Demand Control Ventilation In Schools,Office Buildings,Hospitals And Other Indoor Environments
Brand
Aerosense
Measurement Range
0 to 2000/ 3000/ 5000/ 10000 ppm
Accuracy
+-30ppm +-3%
Operating Humidity Range
0 to 95% RH
Operating Temperature
-10 to 60 deg C
Power
24 VDC,AC
Size
123x70x43 mm
Storage Temperature
-30 to 70 deg C
Storage Temperature for Cold Storage
-40 to 70 deg C
Response Time
150 seconds
Response Time For Cold Storage
70 Seconds
Sampling Interval
3 Sec
CDT-100 Aerosense Carbon Dioxide TransmitterSeries CDT-100, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements. Measurement range upto 10000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.
Product Applications:
Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
RS-485 MODBUS output: (4-wired) Modicon MODBUS RTU mode, which follow Modicon Modbus protocol-settable address ID switch
Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch
Model No. CDT-100Carbon Dioxide TransmitterCDT-100-LCDCarbon Dioxide Transmitter with displayCDT-100-CSCarbon Dioxide Transmitter for cold storageCDT-100-CS-LCDCarbon Dioxide Transmitter for cold storage with display CDT-100-M Carbon Dioxide Transmitter with MODBUS Communication CDT-100-M-LCD Carbon Dioxide Transmitter with MODBUS Communication & display
CDT-100-RLY Aerosense Carbon Dioxide Transmitter
Minimum Order Quantity
1 Piece
Usage
Demand Control Ventilation In Schools,Office Buildings,Hospitals And Other Indoor Environments
Model
Series CDT-100-RLY
Size
123mmx70mmx43mm
Response Time
150 seconds
Brand
Aerosense
Operating Temperature
10 to 60 deg C
Storage temperature
-30 to 70 deg C
CDT-100-RLY Aerosense Carbon Dioxide Transmitter, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements. Measurement range 2000 ppm (5000/10000 ppm) selectable by jumper. It gives analog and Relay output and supports various functions like recalibration function.
Product Applications:
Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
Analog Voltage/Current Output: (6-wired) 0/4-20Ma or 0/2-10V- settable by switch
Models available with SPST (Single Pole, Single Throw, normally open) relay output.
Re-Calibration function: 10 minutes’ manual recalibration is executable with TRB-100 tool
CDT-300 Aerosense Carbon Dioxide Transmitter
Minimum Order Quantity
1 Piece
Model Number
Series CDT-300
Usage/Application
Demand Control Ventilation In Schools,Office Buildings,Hospitals And Other Indoor Environments
Brand
Aerosense
Size
123mmx70mmx43mm
Response Time
150 Seconds
Operating Temperature
-10 to 60 deg C
Operating Humidity range
0 to 95% RH
Storage temperature
-30 to 70 deg C
Power
24 V Dc
CDT-300 Aerosense Carbon Dioxide TransmitterSeries CDT-300, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements. Measurement range upto 70000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.
Product Applications:
Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch