DWYER Differential Pressure Gauges: Applications and Advantages

Oct 26, 2026 by admin 0 Comments , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

DWYER Differential Pressure Gauges: Applications and Advantages

DWYER Differential Pressure Gauges Are Designed To Measure The Pressure Difference Between Two Points In Air And Compatible Non-Corrosive Gases. These Gauges Are Widely Used For Monitoring Air Pressure, Filter Condition, Airflow Resistance And Pressure Differences In Industrial And Commercial Applications.


PRODUCT APPLICATIONS

• HVAC Systems And Air Handling Units (AHU)
• Cleanrooms And Pharmaceutical Manufacturing Plants
• Hospital Operation Theatres (OT) And Isolation Rooms
• HEPA Filters, Pre-Filters And Fine-Filter Monitoring
• Battery Manufacturing Plants And Electronics Industries
• Air Showers, Laminar Airflow Units And Biosafety Cabinets
• Industrial Ventilation And Exhaust Systems
• Dust Collectors, Bag Filters And Industrial Air Filtration Systems
• Compressor Intake Filters And Blower Systems
• Food Processing Plants And Other Industrial Facilities


ADVANTAGES

  • Accurate Differential Pressure Monitoring Within The Specified Model Accuracy
  • Helps Identify Filter Clogging And Increasing Pressure Drop
  • Supports Preventive Maintenance And Timely Filter Replacement
  • Easy-To-Read Dial Display For Convenient Pressure Monitoring
  • Available In Different Pressure Ranges And Configurations, Depending On The Model
  • Suitable For Monitoring Positive, Negative And Differential Pressure Where Supported By The Selected Model
  • Helps Maintain HVAC And Cleanroom Operating Conditions
  • Robust Construction For Suitable Industrial Environments
  • Simple Installation With Compatible Pressure Connections And Accessories.


PRODUCT SELECTION

Select The Appropriate DWYER Differential Pressure Gauge According To The Required Pressure Range, Units Of Measurement, Accuracy, Mounting Arrangement, Process Conditions And Compatibility With The Measured Gas. Available Specifications Vary By Model.


SUPPLY AND SERVICE


ENVIRO TECH INDUSTRIAL PRODUCTS
Supplies Differential Pressure Gauges For HVAC, Cleanroom, Pharmaceutical, Battery Manufacturing And General Industrial Applications. Contact Us For Model Selection, Availability, Technical Specifications And Quotations.


ENVIRO TECH INDUSTRIAL PRODUCTS – QUALITY SINCE 1995


Ex-Stock Availability Depends On The Selected Model. PAN INDIA DELIVERY.


Additional Information:

  • Item Code: DWYER Differential Pressure Gauges: Applications and Advantages
  • WhatsApp No.9871034100,9868958924,9650264867,9716640145,8368866030,8368801023
  • www.envirotechindustrialproduct.com
  • www.envirotechindustrialproducts.com
  • www.envirotechindustrialproducts.net
  • www.envirotechindustrialproduct.net
  • www.envirotechindustrialproductsindia.in
  • www.envirotechindustrialproductsdelhi.com
  • www.envirotechindustrialproduct.info
  • www.envirotechindustrialproducts.info

Series 605 Magnehelic Differential Pressure Indicating Transmitter Wholesaler

Series 605 Magnehelic Differential Pressure Indicating Transmitter

 
Usage/ApplicationMonitor Pressures in Ducts, Rooms,or Total Building Pressures, Filter Monitoring, Local indication of Clean Room Pressures With Process Signal sent to Control Room
BrandDWYER
Model Name/NumberSeries 605
Connection1/8″ female NPT.
Dial Size4″ (101.6 mm) dial face,5″ (127 mm) OD x 2-11/16″ (68.3 mm).
OptionalAir and non-combustible,compatible gases.

The Series 605 Magnehelic Indicating Transmitter provides for both visual monitoring and electronic control of very low differential pressure.The Series 605 is ideal for control applications in building HVAC systems where local indication is desired during routine maintenance checks or necessary when trouble shooting the system.The easily read dial gage is complimented by the two-wire, 4 to 20 mA control signal utilizing the time-proven Dwyer Magnehelic gage mechanical design and Series 600 transmitter technology. The two-wire design with terminal strip on the rear simplifies connection in any 4 to 20 mA control loop powered by a 10 to 35 VDC supply.

Product Applications
:
  • Monitor Pressures in Ducts,
  • Rooms,or Total Building Pressures,
  • Filter Monitoring,
  • Local indication of Clean Room Pressures With Process Signal sent to Control Room

Models & Ordering:
  • Model-605-0
  • Range – 0-.50″ w.c.,max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±3% mechanical accuracy.
  • Model-605-00N
  • Range – .05-0-0.2″ w.c.,max.pressure 25 psi (1.7 bar),±2% electrical accuracy,±4% mechanical accuracy.
  • Model-605-1
  • Range – 0-1.0″ w.c.,max.pressure 25 psi (1.7 bar), ±2% electrical accuracy,±2% mechanical accuracy.
  • Model-605-10 
  • Range – 0-10″ w.c.,max.pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-11
  • Range – .25-0-.25″ w.c.,max. pressure 25 psi (1.7 bar),±2% electrical accuracy,±3% mechanical accuracy.
  • Model-605-125PA
  • Range – 0-125 Pa,max.pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±3% mechanical accuracy.
  • Model-605-2
  • Range – 0-2.0″ w.c.,max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-20
  • Range – 0-20″ w.c.,max.pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-250PA
  • Range – 0-250 Pa,max.pressure 25 psi (1.7 bar), ±2% electrical accuracy,±2% mechanical accuracy.
  • Model-605-3
  • Range – 0-3.0″ w.c.,max.pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-30
  • Range – 0-30″ w.c.,max. pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-50
  • Range – 0-50″ w.c.,max. pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy.
  • Model-605-500PA
  • Range – 0-500 Pa,max. pressure 2 psi (13.79 kPa),±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-6 
  • Range – 0-6.0″ w.c.,max. pressure 2 psi (13.79 kPa),±0.5% electrical accuracy, ±2% mechanical accuracy.
  • Model-605-60PA 
  • Range – 0-60 Pa, max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±4% mechanical accuracy.
 

Dwyer 605-0 Magnehelic Differential Pressure Indicating Transmitter 0-.50 Inch

 
Usage/ApplicationMonitor Pressures in Ducts, Rooms,or Total Building Pressures, Filter Monitoring, Local indication of Clean Room Pressures With Process Signal sent to Control Room
BrandDWYER
Model Name/NumberDwyer 605-0
Power Supply10 to 35 VDC (2-wire)
Range0-.50 Inch
ApplicationsMonitor Pressures in Ducts,Rooms,or Total Building Pressures,Filter Monitoring,Local indication o
Dial Size4″ (101.6 mm) dial face,5″ (127 mm) OD x 2-11/16″ (68.3 mm)
Size4 INCH AND 101.6 mm
Weight1 lb,12.6 oz (811 g)


Dwyer 605-0 Magnehelic Differential Pressure Indicating Transmitter 0-.50 Inch

  • Model: 605-0

Provides for both visual monitoring and electronic control of very low differential pressure. Ideal for control applications in building HVAC/R systems where local indication is desired during routine maintenance checks or necessary when trouble shooting the system.

Dwyer 605-0 MAGNEHELIC, INDICATING TRANSMITTER, 0-.50

  • Easy to read dial gauge is complimented by the two-wire, 4-20 mA control signal utilizing the time-proven Dwyer® Magnehelic® gauge mechanical design and Series 600 transmitter technology.
  • The two-wire design with terminal strip on the rear simplifies connection in any 4-20 mA control loop powered by a 10-35 VDC supply.

Gauge Specifications:

  • Service: Air and non-combustible, compatible gases.
  • Accuracy: +/-3%.
  • Stability: ±1% F.S./yr.
  • Pressure Limits: 25 psi (1.7 bar).
  • Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).
  • Process Connections: 1/8″ female NPT.
  • Size: 4″ (101.6 mm) dial face, 5″ (127 mm) O.D.x 2-11/16″ (68.3 mm).
  • Weight: 1 lb, 12.6 oz (811 g).
  • Agency Approvals: CE.

Transmitter Specifications:

  • Accuracy: +/-2% (includes linearity, hysteresis, repeatability).
  • Temperature Limits: 20 to 120°F(-6.67 to 48.9°C).
  • Compensated Temperature Range: 32 to 120°F (0 to 48.9°C).
  • Thermal Effect: ±0.025% F.S./°F (0.045% F.S./°C).
  • Power Requirements: 10-35 VDC (2-wire).
  • Output Signal: 4 to 20 mA.
  • Zero and Span Adjustments: Protected potentiometers.
  • Loop Resistance: DC; 0-1250 ohms maximum.
  • Current Consumption: DC; 38 mA maximum.
  • Electrical Connections: Screw terminal block.
  • Mounting Orientation: Diaphragm in vertical position.


Dwyer 605-0 Specifications

Gauge
ServiceAir and non-combustible, compatible gases
Stability±1% FS/yr
Temperature Limits20 to 120°F (-6.67 to 48.9°C)
Process Connections???” female NPT
Size4″ (101.6 mm) dial face, 5″ (127 mm) OD x 2-11/16″ (68.3 mm)
Weight1 lb, 12.6 oz (811 g)
Agency ApprovalsCE
Transmitter
Temperature Limits20 to 120°F (-6.67 to 48.9°C)
Compensated Temperature Range32 to 120°F (0 to 48.9°C)
Thermal Effect±0.025% FS/°F (0.045% FS/°C)
Power Requirements10 to 35 VDC (2-wire)
Output Signal4 to 20 mA
Zero and Span AdjustmentsProtected potentiometers
Loop ResistanceDC: 0 to 1250 Ω maximum
Current ConsumptionDC: 38 mA maximum
Electrical ConnectionsScrew terminal block
Mounting OrientationDiaphragm in vertical position