+(91)-9871034100
PHONE NO
07AOSPS8386M1ZM
GST NO

Category: Aerosense Differential Pressure Transmitter Wholesaler

Aerosense Differential Pressure Transmitter Wholesaler

Aerosense Model DPT2500-R8-3W Differential Pressure Transmitter Range 0-2000 Pa

 
Model Name/NumberDPT2500-R8-3W
Frequency RangeRange 0-2000 PA
Power24 VDC
Usage/ApplicationDuct pressure monitoring
Automation GradeAutomatic
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper


The Series DPT2500-R8-3W RANGE 0-2000 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Model DPT2500-R8-3W Differential Pressure Transmitter Range 0-1500 Pa

 

Frequency RangeRange 0-1500 PA
Power24 VDC
Usage/ApplicationDuct pressure monitoring
Automation GradeAutomatic
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
MaterialABS
BrandAerosense

 

The Series DPT2500-R8-3W RANGE 0-1500 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Model DPT2500-R8-3W Differential Pressure Transmitter Range 0-1000 Pa

 
Usage/ApplicationDuct pressure monitoring
Automation GradeAutomatic
Product Weight150 g
RangeRange 0-1000 PA
Response Time0.8 / 4 s selectable by jumper
MaterialABS
BrandAerosense
Max pressure400 kPa


The Series DPT2500-R8-3W RANGE 0-1000 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Model DPT2500-R8-3W Differential Pressure Transmitter Range 0-500 Pa

 
ApplicationBuilding pressure monitoring
Frequency RangeRange 0-500 PA
Power24 VDC
Automation GradeAutomatic
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
MaterialABS
BrandAerosense


The Series DPT2500-R8-3W RANGE 0-500 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Model DPT2500-R8-3W Differential Pressure Transmitter Range 0-250 Pa

 
ApplicationBuilding pressure monitoring
Frequency RangeRange 0-250 PA
Power24 VAC
Automation GradeAutomatic
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
MaterialABS
BrandAerosense


The Series DPT2500-R8-3W RANGE 0-250 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Model DPT2500-R8-3W Differential Pressure Transmitter Range 0-100 Pa

 
Frequency RangeRange 0-100 PA
Power24 VAC
Usage/ApplicationDuct pressure monitoring
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
BrandAerosense


The Series DPT2500-R8-3W RANGE 0-100 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Model DPT2500-R8-3W Differential Pressure Transmitter Range 100-0-100 Pa

 
Frequency RangeRange 100-0-100 PA
Usage/ApplicationDuct pressure monitoring
Automation GradeAutomatic
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
Material GradeABS
BrandAerosense


The Series DPT2500-R8-3W RANGE 100-0-100 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Model DPT2500-R8-3W Differential Pressure Transmitter

 
Power24 VAC
Accuracy+-0.8%
Usage/ApplicationDuct pressure monitoring
Automation GradeAutomatic
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
BrandAerosense
Max Pressure400 kPa
Ambient Humidity0 to 95% RH

 

The Series DPT2500-R8-3W Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter condition monitoring


Range:

  • 100-0-100 Pa
  • 0-100 Pa
  • 0-250 Pa
  • 0-500 Pa
  • 0-1000 Pa
  • 0-1500 Pa
  • 0-2000 Pa
  • 0-2500 Pa

Aerosense Differential Pressure Transmitter Range 150 – 0 – 150 Pac

 
Minimum Order Quantity1 Number
Model Name/NumberDPT250-R8-3W
Frequency RangeRange 150 – 0 – 150 PAC
Power24 VAC
Usage/ApplicationDuct pressure monitoring
Automation GradeAutomatic
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
Warranty1 Year
Size90,0 x 71,5 x 36,0 mm
MaterialABS
BrandAerosense


The Series DPT250-R8-3W RANGE 150 – 0 – 150 PAC Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Differential Pressure Transmitter Range 100 – 0 – 100 Pac

 
Model Name/NumberDPT250-R8-3W
Frequency RangeRange 100 – 0 – 100 PAC
Power24 VAC
Usage/ApplicationDuct pressure monitoring
Automation GradeAutomatic
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
MaterialABS
BrandAerosense

The Series DPT250-R8-3W RANGE 100 – 0 – 100 PAC Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring
 

Aerosense Differential Pressure Transmitter Range 50 – 0 – 50 Pac

 
ApplicationBuilding pressure monitoring
Model Name/NumberDPT250-R8-3W
Frequency RangeRange 50 – 0 – 50 PAC
Power24 VAC
Automation GradeAutomatic
Response Time0.8 / 4 s selectable by jumper
Size90,0 x 71,5 x 36,0 mm
MaterialABS
Net Weight150 g
BrandAerosense


The Series DPT250-R8-3W RANGE 50 – 0 – 50 PAC Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Differential Pressure Transmitter Range 25 – 0 – 25 Pac

 
ApplicationFilter condition monitoring
Frequency RangeRange 25 – 0 – 25 PAC
Product Weight150 g
Rated Supply Voltage24 VAC
Response Time0.8 / 4 s selectable by jumper
BrandAerosense Singapore

The Series DPT250-R8-3W RANGE 25 – 0 – 25 PAC Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring
 
Yes! I am interested

Aerosense Differential Pressure Transmitter Range 0-250 Pac

 
Frequency RangeRange 0-250 PAC
Power24 VAC
Usage/ApplicationDuct pressure monitoring
Automation GradeManual
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
Size90,0 x 71,5 x 36,0 mm
MaterialABS
BrandAerosense
Model Number/NameDPT250-R8-3W


The Series DPT250-R8-3W RANGE 0-250 PAC Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Differential Pressure Transmitter Range 0-100 Pac

 
Frequency RangeRange 0-100 PAC
Power24 VAC
Usage/ApplicationFilter condition monitoring
Automation GradeManual
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
BrandAerosense
Model Number/NameDPT250-R8-3W


The Series DPT250-R8-3W RANGE 0-100 PAC Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Differential Pressure Transmitter Range 0-50 Pac

 
ApplicationBuilding Pressure Monitoring
Frequency RangeRange 0-50 PAC
Product Weight150 g
Rated Supply Voltage24 VAC
Response Time0.8 / 4 s selectable by jumper
BrandAerosense


The Series DPT250-R8-3W RANGE 0-50 PAC Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Differential Pressure Transmitter Range 0-25 Pac

 
Frequency Range0-25 PAC
Usage/ApplicationFilter condition monitoring
Weight150 g
Response Time0.8 / 4 s selectable by jumper
RangeRange 0-25 PAC
BrandAerosense


The Series DPT250-R8-3W RANGE 0-25 PAC Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Model DPT250-R8-3W Differential Pressure Transmitter

 
Model Name/NumberDPT250-R8-3W
Power24 VAC
Usage/ApplicationDuct pressure monitoring
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
BrandAerosense

 

The Series DPT250-R8-3W Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter condition monitoring


Range:

  • 0-25 Pa
  • 0-50 Pa
  • 0-100 Pa
  • 0-250 Pa
  • 25-0-25 Pa
  • 50-0-50 Pa
  • 100-0-100 Pa
  • 150-0-150 Pa

Aerosense Series DPT-R8-3W Differential Pressure Transmitter

 
Usage/ApplicationAir And Non-Aggressive Gases
Model Name/NumberAerosense Series DPT-R8-3W
BrandAerosense
Voltage24 VAC or VDC +- 10%
Accuracy+-0.8%,or (+-1% <250 Pa)
Product Weight150 g


The Series DPT-R8-3W Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds. The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter condition monitoring
  • Note! Supply voltage must be connected one hour before the 0-point adjustment is carried out.
  • Loose both tubes from the pressure inlets + and –
  • Push zero button until the red led turns ON.
  • Wait until LED turns off and then install tubes again to the pressure inlets.

 

It is recommended to adjust the zero point every 12 months during normal operation.
If the transmitter is equipped with automatic zero element the manual push button adjustment is not required.

 

AZ-calibration is a function in the form of an automatic zeroing circuit built into the PCB. The AZ-calibration electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The AZ-calibration eliminates all output signal drift due to thermal, electronic or mechanical effects, as well as the need for technicians to remove high and low pressure tubes when performing initial or periodic transmitter zero point calibration. The AZ adjustment takes 4 seconds. To avoid conflict with the BAS system, the output and display values will freeze to the latest measured value, after which the device returns to its normal measuring mode. Transmitters equipped with the AZ-calibration are virtually maintenance free.

Specifications:

  • Service: Air and non-aggressive gases Measuring element: Piezoresistive Accuracy: ±0.8%, or (±1% <250 Pa)
  • Measuring unit: Selectable by jumper (Pa, kPa, mbar, inchWC, mmWC, psi)
  • Response Time: 0.8 / 4 s selectable by jumper Max pressure: 400 kPa
  • Electrical interface :
  • Supply voltage: 24 VAC or VDC ± 10 %
  • Power co nsumption: <1.0 W (<1.5W with lout 20mA)
  • Output signal :
  • 0…10 VDC, Load R minimum 1 kQor
  • 4…20 mA, maximum load 500Q
  • Materials:
  • Housing: ABS
  • Cover: PC
  • Pressure connections: ABS
  • Connections:
  • Electrical co nnections: 4 screw terminals, max 1.5 mm2
  • Cable entry: M16
  • Pressure connections: Male 5,0 mm and 6,3 mm Weight: 150 g
  • Dimensions: 90,0 x 71,5 x 36,0 mm
  • General ambient condition:
  • Temperature range:
  • Operation -10…+50°C (-5…+50°C for -AZ model)
  • Storage: -20…+70°C
  • Ambient humidity: 0 to 95% RH
  • Safety:
  • Protection standard: IP54
  • Conformance: Meets the requirements for CE marking:
  • EMC directive 2004/108/EY
  • Rohs Directive 2002/95/EY
  • Optional Accessories:
  • Plastic Pressure Tips
  • 2m Tubes

Aerosense Model DPT2500-R8-3W Differential Pressure Transmitter Range 0-2500 Pa

 
ApplicationBuilding pressure monitoring
Model Name/NumberDPT2500-R8-3W
Frequency RangeRange 0-2500 PA
Power24 VDC
Automation GradeAutomatic
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
MaterialABS
BrandAerosense


The Series DPT2500-R8-3W RANGE 0-2500 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Model DPT7000-R8-3W Differential Pressure Transmitter

 
Frequency RangeDPT7000-R8-3W
Accuracy+-0.8%
Usage/ApplicationBuilding pressure monitoring
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
BrandAerosense
Max Pressure400 kPa

 

The Series DPT7000-R8-3W Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter condition monitoring


Range:

  • 0-1000 Pa
  • 0-1500 Pa
  • 0-2000 Pa
  • 0-2500 Pa
  • 0-3000 Pa
  • 0-4000 Pa
  • 0-5000 Pa
  • 0-7000 Pa

Aerosense Model DPT7000-R8-3W Differential Pressure Range 0-1000 Pa

 
ApplicationDuct pressure monitoring
Frequency RangeRange 0-1000 PA
Power24 VDC
Accuracy+-8%
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
BrandAerosense
Max pressure400 kPa


The Series DPT7000-R8-3W RANGE 0-1000 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring


Range:

  • 0-1000 PA

Aerosense Model DPT7000-R8-3W Differential Pressure Range 0-1500 Pa

 
Frequency Range0-1500 PA
Power24 VDC
Usage/ApplicationBuilding pressure monitoring
Automation GradeAutomatic
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
MaterialABS
Certification RequiredYes
BrandAerosense


The Series DPT7000-R8-3W RANGE 0-1500 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Model DPT7000-R8-3W Differential Pressure Range 0-2000 Pa

 
ApplicationDuct pressure monitoring
Frequency RangeRange 0-2000 PA
Power24 VDC
Automation GradeAutomatic
Product Weight150 g
Response Time0.8 / 4 s selectable by jumper
MaterialABS
BrandAerosense
Model Number/NameDPT7000-R8-3W


The Series DPT7000-R8-3W RANGE 0-2000 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring


Range:

  • 0-2000 PA

Aerosense Model DPT7000-R8-3W Differential Pressure Range 0-2500 Pa

 
ApplicationBuilding pressure monitoring
Frequency RangeRange 0-2500 PA
Power24 VDC
Automation GradeAutomatic
Response Time0.8 / 4 s selectable by jumper
Weight150 g
Watted MaterialsABS
BrandAerosense


The Series DPT7000-R8-3W RANGE 0-2500 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Model DPT7000-R8-3W Differential Pressure Range 0-3000 Pa

 
ApplicationDuct pressure monitoring
Frequency RangeRANGE 0-3000 PA
Power24 VDC
Automation GradeAutomatic
Response Time0.8 / 4 s selectable by jumper
Weight150 g
Warranty1 ear
MaterialABS
BrandAEROSENSE Singapore


The Series DPT7000-R8-3W RANGE 0-3000 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring


Range:

  • 0-3000 PA

Aerosense Model DPT7000-R8-3W Differential Pressure Range 0-4000 Pa

 
ApplicationDuct pressure monitoring
Model Name/NumberDPT7000-R8-3W
Frequency Range0-4000 PA
Power24 VDC
Automation GradeAutomatic
Response Time0.8 / 4 s selectable by jumper
Weight150 g
Warranty1 year
Watted MaterialsABS
BrandAerosense


The Series DPT7000-R8-3W RANGE 0-4000 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring


Range:

  • 0-4000 PA

Aerosense Model DPT7000-R8-3W Differential Pressure Range 0-5000 Pa

 
Frequency Range0-5000 PA
Power24 VDC
Usage/ApplicationBuilding pressure monitoring
Automation GradeAutomatic
Response Time0.8 / 4 s selectable by jumper
Weight150 g
MaterialABS
Certification RequiredYes
BrandAerosense


The Series DPT7000-R8-3W RANGE 0-5000 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Model DPT7000-R8-3W Differential Pressure Range 0-7000 Pa

 
ApplicationDuct pressure monitoring
Frequency Range0-7000 PA
Power24 VDC
Automation GradeAutomatic
Response Time0.8 / 4 s selectable by jumper
MaterialABS
Net Weight150 g
BrandAerosense
Model Number/NameDPT7000-R8-3W


The Series DPT7000-R8-3W RANGE 0-7000 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring

Aerosense Differential Pressure Cum Flow Transmitter

 
Accuracy+/-2%
Temperature Range-20-120degC
BrandAerosense
Model Number/NameDPT-Flow-1000-D
Pressure range0.001MPa-35MPa
MediumLiquid,Gas and Steam

Aerosense Differential Pressure cum Flow Transmitter is technically engineered type of flow transmitter that is especially used in HVAC/R industry to control the flow, velocity and static of air pressure. Apart from measuring the flow of air control, this type of transmitter is used in the other major applications such as VAV domain and air flow monitoring across centrifugal fans & blowers. It supports low power consumption as well as enabled with the zero point calibration system.

Features:

  • VAV applications
  • Minimum resistance
  • Piezo resistive

Aerosense Model DPT250-R8-3W-LCD Differential Pressure Transmitter

 
Model NumberDPT250-R8-3W-LCD
BrandAEROSENSE Singapore
Power24 VAC
Usage/ApplicationBuilding pressure monitoring
Automation GradeAutomatic
Product Weight150 G


The Series DPT250-R8-3W-LCD Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter condition monitoring


Range:

  • 0-25 Pa
  • 0-50 Pa
  • 0-100 Pa
  • 0-250 Pa
  • 25-0-25 Pa
  • 50-0-50 Pa
  • 100-0-100 Pa
  • 150-0-150 Pa

Aerosense Model DPT2500-R8-3W-LCD Differential Pressure Transmitter

 
Model NumberDPT2500-R8-3W-LCD
BrandAEROSENSE Singapore
Power24 VAC
Usage/ApplicationDuct pressure monitoring
Automation GradeAutomatic
Product Weight150 g

The Series DPT2500-R8-3W-LCD Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds.

The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter condition monitoring

Range:
  • 100-0-100 Pa
  • 0-100 Pa
  • 0-250 Pa
  • 0-500 Pa
  • 0-1000 Pa
  • 0-1500 Pa
  • 0-2000 Pa
  • 0-2500 Pa
 

Aerosense Model DPT7000-R8-3W-LCD Differential Pressure Transmitter

 
Model NumberDPT7000-R8-3W-LCD
BrandAerosense Singapore
Power24 VDC
Usage/ApplicationDuct pressure monitoring
Automation GradeAutomatic
Product Weight150 g


The Series DPT7000-R8-3W-LCD RANGE 0-7000 PA Differential Pressure Transmitter is an Extremely Versatile Transmitter for Monitoring Pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The Auto-Zero adjustment takes 4 seconds. The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and Auto-Zero feature available.

 

Product Applications:

  • Building pressure monitoring
  • Duct pressure monitoring
  • Filter Condition Monitoring


Range:

  • 0-1000 Pa
  • 0-1500 Pa
  • 0-2000 Pa
  • 0-2500 Pa
  • 0-3000 Pa
  • 0-4000 Pa
  • 0-5000 Pa
  • 0-7000 Pa

Aerosense Series AVT Air Velocity Cum Temperature Transmitter

 
ModelAVT
BrandAerosense
Display TypeAnalog
Usage/ApplicationClean room fresh air supply
Size/Dimension45.7 x 12.7 mm
MaterialCase ABS Probe Stainless steel 304


Series AVT Air Velocity Transmitter is the ideal instrument for measurement of Air Velocity and Temperature. The field selectable ranges provides the versatility to be selected for several air flow applications. The optional LED produces a complete, low cost solution for local indication of air flow.

Product Applications:

  • Exhaust stack air flow monitoring
  • Clean room fresh air supply
  • HVAC air velocity measurements
  • Fan supply
  • Air Control in drying processes
    • Media compatibility: Dry air or non-aggressive gases
    • Measuring units: m/s and °C
    • Measuring element: Temperature: ntc10k & Velocity: Pt1000
    • Operating temperature: 0…50 °C
    • Storage temperature: -20…70 °C
    • Humidity: 0 to 95 % RH, non-condensing
    • Velocity Range: 0-2 m/s, 0-10 m/s, 0-20 m/s
    • Temperature Range: 0-50 °C
    • Velocity Accuracy:
      • Range: 0-2 m/s: <0.1 m/s + 5 % from reading
      • Range: 0-10 m/s: <0.5 m/s + 5 % from reading
      • Range: 0-20 m/s: <1.0 m/s + 5 % from reading
    • Temperature Accuracy: <0.5° C (velocity > 0.5 m/s)
    • Case: 90.0 x 95.0 x 36.0 mm
    • Probe: OD 10 mm, length 210 mm from bottom of the cover
    • Immersion Length with Flange: Adjustable 50-180 mm
    • Weight: 220 g
    • Mounting: 2 screw holes, 4.0 mm
    • Materials:
      • Case: ABS
      • Probe: Stainless steel 304
    • Mounting flange: LLPDP
    • Protection standard: IP54
    • Display: 3 1/2 digit LCD backlit display
    • Size: 45.7 x 12.7 mm
    • Power supply & signal out: 4-screw terminal block 12-24 AWG (0.2-1.5 mm2)
    • Relay Out: 3-screw terminal block 12-24 AWG (0.2-1.5 mm2)
    • Cable entry: M16
    • Input: 24 VDC / 24 VAC ± 10 % Current consumption 35 mA (50 mA with relay) + 40 mA with mA-outs
    • Output signal 1: (T out)
      • 0-10 V (linear to temperature) L min 1 kQ
      • 4-20 mA (linear to temperature) L max 400 Q
    • Output signal 2: (V out)
      • 0-10 V (linear to m/s) L min 1 kQ
      • 4-20 mA (linear to m/s) L max 400 Q
    • Relay Out: 3-screw terminal block (NC, COM, NO) 12-24 AWG (0.2-1.5 mm2) Potential free SPDT 250 VAC, 6A / 30 VDC, 6 A adjustable switching point and hysteresis
      • For Standard Air Velocity Transmitter Model AVT
      • For Display Models AVT-D &
      • For Relay Models AVT-D-R

Conformance: Meets the requirements for CE marking

Aerosense Series AVT Air Velocity Cum Temperature Transmitter with Display And Relay

 
MaterialCase ABS Probe Stainless steel 304
BrandAEROSENSE Singapore
Display Type3 1/2 Digit LCD Backlit Display
Model NumberAVT-D-R
Usage/ApplicationHVAC air velocity measurements


Series AVT Air Velocity Transmitter is the ideal instrument for measurement of Air Velocity and Temperature. The field selectable ranges provides the versatility to be selected for several air flow applications. The optional LED produces a complete, low cost solution for local indication of air flow.

Product Applications:

  • Exhaust stack air flow monitoring
  • Clean room fresh air supply
  • HVAC air velocity measurements
  • Fan supply
  • Air Control in drying processes
    • Media compatibility: Dry air or non-aggressive gases
    • Measuring units: m/s and °C
    • Measuring element: Temperature: ntc10k & Velocity: Pt1000
    • Operating temperature: 0…50 °C
    • Storage temperature: -20…70 °C
    • Humidity: 0 to 95 % RH, non-condensing
    • Velocity Range: 0-2 m/s, 0-10 m/s, 0-20 m/s
    • Temperature Range: 0-50 °C
    • Velocity Accuracy:
      • Range: 0-2 m/s: <0.1 m/s + 5 % from reading
      • Range: 0-10 m/s: <0.5 m/s + 5 % from reading
      • Range: 0-20 m/s: <1.0 m/s + 5 % from reading
    • Temperature Accuracy: <0.5° C (velocity > 0.5 m/s)
    • Case: 90.0 x 95.0 x 36.0 mm
    • Probe: OD 10 mm, length 210 mm from bottom of the cover
    • Immersion Length with Flange: Adjustable 50-180 mm
    • Weight: 220 g
    • Mounting: 2 screw holes, 4.0 mm
    • Materials:
      • Case: ABS
      • Probe: Stainless steel 304
    • Mounting flange: LLPDP
    • Protection standard: IP54
    • Display: 3 1/2 digit LCD backlit display
    • Size: 45.7 x 12.7 mm
    • Power supply & signal out: 4-screw terminal block 12-24 AWG (0.2-1.5 mm2)
    • Relay Out: 3-screw terminal block 12-24 AWG (0.2-1.5 mm2)
    • Cable entry: M16
    • Input: 24 VDC / 24 VAC ± 10 % Current consumption 35 mA (50 mA with relay) + 40 mA with mA-outs
    • Output signal 1: (T out)
      • 0-10 V (linear to temperature) L min 1 kQ
      • 4-20 mA (linear to temperature) L max 400 Q
    • Output signal 2: (V out)
      • 0-10 V (linear to m/s) L min 1 kQ
      • 4-20 mA (linear to m/s) L max 400 Q
    • Relay Out: 3-screw terminal block (NC, COM, NO) 12-24 AWG (0.2-1.5 mm2) Potential free SPDT 250 VAC, 6A / 30 VDC, 6 A adjustable switching point and hysteresis
      • For Standard Air Velocity Transmitter Model AVT
      • For Display Models AVT-D &
      • For Relay Models AVT-D-R

Conformance: Meets the requirements for CE marking