+(91)-9871034100
PHONE NO
07AOSPS8386M1ZM
GST NO

Category: Series 605 Magnehelic Differential Pressure Indicating Transmitter Wholesaler

Series 605 Magnehelic Differential Pressure Indicating Transmitter Wholesaler

Series 605 Magnehelic Differential Pressure Indicating Transmitter

 
Usage/ApplicationMonitor Pressures in Ducts, Rooms,or Total Building Pressures, Filter Monitoring, Local indication of Clean Room Pressures With Process Signal sent to Control Room
BrandDWYER
Model Name/NumberSeries 605
Connection1/8″ female NPT.
Dial Size4″ (101.6 mm) dial face,5″ (127 mm) OD x 2-11/16″ (68.3 mm).
OptionalAir and non-combustible,compatible gases.

The Series 605 Magnehelic Indicating Transmitter provides for both visual monitoring and electronic control of very low differential pressure.The Series 605 is ideal for control applications in building HVAC systems where local indication is desired during routine maintenance checks or necessary when trouble shooting the system.The easily read dial gage is complimented by the two-wire, 4 to 20 mA control signal utilizing the time-proven Dwyer Magnehelic gage mechanical design and Series 600 transmitter technology. The two-wire design with terminal strip on the rear simplifies connection in any 4 to 20 mA control loop powered by a 10 to 35 VDC supply.

Product Applications
:
  • Monitor Pressures in Ducts,
  • Rooms,or Total Building Pressures,
  • Filter Monitoring,
  • Local indication of Clean Room Pressures With Process Signal sent to Control Room

Models & Ordering:
  • Model-605-0
  • Range – 0-.50″ w.c.,max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±3% mechanical accuracy.
  • Model-605-00N
  • Range – .05-0-0.2″ w.c.,max.pressure 25 psi (1.7 bar),±2% electrical accuracy,±4% mechanical accuracy.
  • Model-605-1
  • Range – 0-1.0″ w.c.,max.pressure 25 psi (1.7 bar), ±2% electrical accuracy,±2% mechanical accuracy.
  • Model-605-10 
  • Range – 0-10″ w.c.,max.pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-11
  • Range – .25-0-.25″ w.c.,max. pressure 25 psi (1.7 bar),±2% electrical accuracy,±3% mechanical accuracy.
  • Model-605-125PA
  • Range – 0-125 Pa,max.pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±3% mechanical accuracy.
  • Model-605-2
  • Range – 0-2.0″ w.c.,max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-20
  • Range – 0-20″ w.c.,max.pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-250PA
  • Range – 0-250 Pa,max.pressure 25 psi (1.7 bar), ±2% electrical accuracy,±2% mechanical accuracy.
  • Model-605-3
  • Range – 0-3.0″ w.c.,max.pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-30
  • Range – 0-30″ w.c.,max. pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-50
  • Range – 0-50″ w.c.,max. pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy.
  • Model-605-500PA
  • Range – 0-500 Pa,max. pressure 2 psi (13.79 kPa),±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-6 
  • Range – 0-6.0″ w.c.,max. pressure 2 psi (13.79 kPa),±0.5% electrical accuracy, ±2% mechanical accuracy.
  • Model-605-60PA 
  • Range – 0-60 Pa, max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±4% mechanical accuracy.
 

Dwyer 605-0 Magnehelic Differential Pressure Indicating Transmitter 0-.50 Inch

 
Usage/ApplicationMonitor Pressures in Ducts, Rooms,or Total Building Pressures, Filter Monitoring, Local indication of Clean Room Pressures With Process Signal sent to Control Room
BrandDWYER
Model Name/NumberDwyer 605-0
Power Supply10 to 35 VDC (2-wire)
Range0-.50 Inch
ApplicationsMonitor Pressures in Ducts,Rooms,or Total Building Pressures,Filter Monitoring,Local indication o
Dial Size4″ (101.6 mm) dial face,5″ (127 mm) OD x 2-11/16″ (68.3 mm)
Size4 INCH AND 101.6 mm
Weight1 lb,12.6 oz (811 g)


Dwyer 605-0 Magnehelic Differential Pressure Indicating Transmitter 0-.50 Inch

  • Model: 605-0

Provides for both visual monitoring and electronic control of very low differential pressure. Ideal for control applications in building HVAC/R systems where local indication is desired during routine maintenance checks or necessary when trouble shooting the system.

Dwyer 605-0 MAGNEHELIC, INDICATING TRANSMITTER, 0-.50

  • Easy to read dial gauge is complimented by the two-wire, 4-20 mA control signal utilizing the time-proven Dwyer® Magnehelic® gauge mechanical design and Series 600 transmitter technology.
  • The two-wire design with terminal strip on the rear simplifies connection in any 4-20 mA control loop powered by a 10-35 VDC supply.

Gauge Specifications:

  • Service: Air and non-combustible, compatible gases.
  • Accuracy: +/-3%.
  • Stability: ±1% F.S./yr.
  • Pressure Limits: 25 psi (1.7 bar).
  • Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).
  • Process Connections: 1/8″ female NPT.
  • Size: 4″ (101.6 mm) dial face, 5″ (127 mm) O.D.x 2-11/16″ (68.3 mm).
  • Weight: 1 lb, 12.6 oz (811 g).
  • Agency Approvals: CE.

Transmitter Specifications:

  • Accuracy: +/-2% (includes linearity, hysteresis, repeatability).
  • Temperature Limits: 20 to 120°F(-6.67 to 48.9°C).
  • Compensated Temperature Range: 32 to 120°F (0 to 48.9°C).
  • Thermal Effect: ±0.025% F.S./°F (0.045% F.S./°C).
  • Power Requirements: 10-35 VDC (2-wire).
  • Output Signal: 4 to 20 mA.
  • Zero and Span Adjustments: Protected potentiometers.
  • Loop Resistance: DC; 0-1250 ohms maximum.
  • Current Consumption: DC; 38 mA maximum.
  • Electrical Connections: Screw terminal block.
  • Mounting Orientation: Diaphragm in vertical position.


Dwyer 605-0 Specifications

Gauge
ServiceAir and non-combustible, compatible gases
Stability±1% FS/yr
Temperature Limits20 to 120°F (-6.67 to 48.9°C)
Process Connections???” female NPT
Size4″ (101.6 mm) dial face, 5″ (127 mm) OD x 2-11/16″ (68.3 mm)
Weight1 lb, 12.6 oz (811 g)
Agency ApprovalsCE
Transmitter
Temperature Limits20 to 120°F (-6.67 to 48.9°C)
Compensated Temperature Range32 to 120°F (0 to 48.9°C)
Thermal Effect±0.025% FS/°F (0.045% FS/°C)
Power Requirements10 to 35 VDC (2-wire)
Output Signal4 to 20 mA
Zero and Span AdjustmentsProtected potentiometers
Loop ResistanceDC: 0 to 1250 Ω maximum
Current ConsumptionDC: 38 mA maximum
Electrical ConnectionsScrew terminal block
Mounting OrientationDiaphragm in vertical position