+(91)-9871034100
PHONE NO
07AOSPS8386M1ZM
GST NO

Category: Temperature Transmitters Wholesale India

Temperature Transmitters Wholesale India

Universal Type Temperature Transmitter

 
Minimum Order Quantity12 Piece
Usage/ApplicationConverts all type of Thermocouple, RTD, Ohms, mV into 4 to 20mA analogue output
Model Name/NumberGALAXY
BrandGALAXY
Rated Supply Voltage10 to 32 VDC
Supply Voltage Limits10 to 32 VDC
Output Type2 Wire, 4 to 20mA
Part TypeUniversal Type Temperature Transmitter
Country of OriginMade in India
Input ValueAll type of Thermocouple, RTDs, Ohms, mV
Programming & CalibrationUser friendly software and a USB Calibrator
MountingHead Mount

Universal Type Temperature Transmitter

PC Programmable Head Mount Temperture Transmitter Which Converts All Tc, RTD, Ohms Mv Into a Scalable Analogue Signal Of 4 to 20ma.

Performance

  • 2-Wire Technology, 4 to 20ma Analogue Output.
  • High Accuracy In Total Ambient Temperature Range.
  • Internal Cold Junction Compensation.
  • Wide Voltage Supply Range.
  • Customer Specific Measurement Range Setting Or Expanded Setup.
  • Simple And User Friendly Software.
  • USB Communication.

INPUT

  • Type : TC, RTD, Ohms, mV
  • Measurement Ranges : -200 to 850°c
  • Connection Type : 3-Wire Connection

OUTPUT

  • Output Signal : 2 Wire, 4 to 20ma Scalable Analogue Signal Output

  • Current Alarm Output : 3. 6ma or 22ma When Sensor Damage Or Break.

 
TECHNICAL SPECIFICATIONS

  • Damp : 0-32s
  • Current Limit : ≤ 22ma
  • Saturation Current : Low 3. 8ma ; High 20. 6ma
  • Response Time : ≤ 0. 8s
  • Data Refresh Rate : 4 Times/Sec
  • Accuracy : ± 0. 1%
  • Stability :0. 01 ??c
  • Power Supply : 10 to 32 VDC 

Temperature Transmitters

 
Minimum Order Quantity12 Number
Usage/ApplicationConverts RTD & Thermocouple Input into linear scalable 4 to 20mA.
Model Name/NumberTR 213
BrandGALAXY
Voltage24 VDC
Rated Supply Voltage24 VDC
Output Type2 Wire,4 to 20mA
Country of OriginMade in India
Input ValueUniversal All type of RTD & Thermocouple Input

Temperature Transmitters

TT 210 is a Head Mount Non isolated universal temperature transmitter for resistance thermometers (RTD), thermocouples (TC), resistance & voltage (mV) which converts all these data signals into scalable 4 to 20mA analogue output signal.
 
This is a user programmable temperature transmitter which can be programmed for input signal from ANDROID SMART PHONE or LAPTOP  via data cable & user friendly operating software.
 
Performance Features:


  • 2 wire technology 4 to 20 mA analogue output.
  • High accuracy in total ambient temperature range.
  • An internal temperature sensor for active temperature compensation.
  • Wide voltage supply range.
  • Customer specific measurement range setting.
  • Simple & user friendly software
  • USB Communication


Technical Data

  • Input RTD, TC, OHM, mV
  • Output 4 to 20 mA
  • Supply voltage 7.5 to 45 VDC
  • Cold junction Internal
  • Influence of ambient Negligible
  • Load influence Negligible
  • Power supply influence Negligible
  • Resolution 0.3 uA
  • Installation Sensor head from B
  • Operation PC – programmable
  • Weight Approx. 35 GMS
  • Dimensions 44 MM × 22. 5 MM (Φ × H)
 

RTD PT 100 Temperature Transmitter

 
Minimum Order Quantity12 Piece
Usage/ApplicationUse for converting RTD Signal into scalable analog Input signal 4 to 20mA
Model Name/NumberRTD PT 100
BrandGALAXY
Voltage10 to 32 VDC
Accuracy+- 0.1%
Protection TypeRTD PT 100 Temperature Transmitter
Output Type4 to 20mA
Part TypeRTD PT 100 Temperature Transmitter
Country of OriginMade in India
ProgrammingCan be programmed with user freindly software & USB

RTD PT 100 Temperature Transmitter

PC Programmable Head Mount Temperture Transmitter Which Converts All Tc, RTD, Ohms Mv Into a Scalable Analogue Signal Of 4 to 20ma.

Performance

  • 2-Wire Technology, 4 to 20ma Analogue Output.
  • High Accuracy In Total Ambient Temperature Range.
  • Internal Cold Junction Compensation.
  • Wide Voltage Supply Range.
  • Customer Specific Measurement Range Setting Or Expanded Setup.
  • Simple And User Friendly Software.
  • USB Communication.

INPUT

  • Type : TC, RTD, Ohms, mV ( RTD PT 100 )
  • Measurement Ranges : -200 to 850°c
  • Connection Type : 3-Wire Connection

OUTPUT

  • Output Signal : 2 Wire, 4 to 20ma Scalable Analogue Signal Output

  • Current Alarm Output : 3. 6ma or 22ma When Sensor Damage Or Break.

 
TECHNICAL SPECIFICATIONS

  • Damp : 0-32s
  • Current Limit : ≤ 22ma
  • Saturation Current : Low 3. 8ma ; High 20. 6ma
  • Response Time : ≤ 0. 8s
  • Data Refresh Rate : 4 Times/Sec
  • Accuracy : ± 0. 1%
  • Stability :0. 01 ??c
  • Power Supply : 10 to 32 VDC