Dwyer Series 668B/D Compact Differential Pressure Transmitter Wholesaler DELHI

Series 668B/D Compact Differential Pressure Transmitter

 
Minimum Order Quantity1 Number
Usage/ApplicationHVAC and VAV Control,Clean rooms and Isolation Rooms,Duct Static Pressure Measurement
Model Name/NumberSeries 668B/D
BrandDWYER USA
Product Weight4.0 oz (113 g).
Supply Voltage Limits12 to 32 VDC.
Output Type4 to 20 mA (2-wire), 0 to 10 VDC (3-wire), or 0 to 5 VDC (3-wire).
Part TypeSeries 668B/D Compact Differential Pressure Transmitter
Country of OriginMade in India

Series 668B/D Compact Differential Pressure Transmitter

Model Description

  • 668B-01-1-CDPT,4 to 20 mA,0 to 0.1″ w.c.
  • 668B-02-1-CDPT,4 to 20 mA,0 to 0.25″ w.c.
  • 668B-02-2-CDPT,0 to 10 VDC,0 to 0.25″ w.c.
  • 668B-02-3-CDPT,0 to 5 VDC,0 to 0.25″ w.c.
  • 668B-03-1-CDPT,4 to 20 mA,0 to 0.5″ w.c.
  • 668B-03-2-CDPT,0 to 10 VDC,0 to 0.5″ w.c.
  • 668B-03-3-CDPT,0 to 5 VDC,0 to 0.5″ w.c.
  • 668B-04-1-CDPT,4 to 20 mA,0 to 1.0″ w.c.
  • 668B-04-2-CDPT,0 to 10 VDC,0 to 1″ w.c.
  • 668B-04-3-CDPT,0 to 5 VDC,0 to 1″ w.c.
  • 668B-05-1-CDPT,4 to 20 mA,0 to 2.5″ w.c.
  • 668B-05-2-CDPT,0 to 10 VDC,0 to 2.5″ w.c.
  • 668B-05-3-CDPT,0 to 5 VDC,0 to 2.5″ w.c.
  • 668B-06-1-CDPT,4 to 20 mA,0 to 5″ w.c.
  • 668B-06-2-CDPT,0 to 10 VDC,0 to 5″ w.c.
  • 668B-07-1-CDPT,4 to 20 mA,0 to 10″ w.c.
  • 668B-08-1-CDPT,4 to 20 mA,0 to 25″ w.c.
  • 668B-09-1-CDPT,4 to 20 mA,0 to 50″ w.c.
  • 668B-10-1-CDPT,4 to 20 mA,0 to 100″ w.c.
  • 668B-12-1-CDPT,4 to 20 mA,0 to ±0.1″ w.c.
  • 668B-12-2-CDPT,0 to 10 VDC,0 to ±0.1″ w.c.
  • 668B-12-3-CDPT,0 to 5 VDC,0 to ±0.1″ w.c.
  • 668B-13-1-CDPT,4 to 20 mA,0 to ±0.25″ w.c.
  • 668B-13-2-CDPT,0 to 10 VDC,0 to ±0.25″ w.c.
  • 668B-13-3-CDPT,0 to 5 VDC,0 to ±0.25″ w.c.
  • 668B-14-1-CDPT,4 to 20 mA,0 to ±0.5″ w.c.
  • 668B-15-1-CDPT,4 to 20 mA,0 to ±1″ w.c.
  • 668B-16-1-CDPT,4 to 20 mA,0 to ±2.5″ w.c.
  • 668B-17-1-CDPT,4 to 20 mA,0 to ±5.0″ w.c.
  • 668B-18-1-CDPT,4 to 20 mA,0 to ±10″ w.c.
  • 668B-19-1-CDPT,4 to 20 mA,0 to ±25″ w.c.
  • 668B-21-1-CDPT,4 to 20 mA,0 to 0.2″ w.c.
  • 668B-21-2-CDPT,0 to 10 VDC,0 to 0.2″ w.c.
  • 668B-22-1-CDPT,4 to 20 mA,0 to 0.4″ w.c.
  • 668B-22-2-CDPT,0 to 10 VDC,0 to 0.4″ w.c.
  • 668B-22-3-CDPT,0 to 5 VDC,0 to 0.4″ w.c.
  • 668D-01-1-CDPT,4 to 20 mA,0 to 0.1″ w.c.
  • 668D-02-1-CDPT,4 to 20 mA,0 to 0.25″ w.c.
  • 668D-02-2-CDPT,0 to 10 VDC,0 to 0.25″ w.c.
  • 668D-03-1-CDPT,4 to 20 mA,0 to 0.5″ w.c.
  • 668D-03-2-CDPT,0 to 10 VDC,0 to 0.5″ w.c.
  • 668D-04-1-CDPT,4 to 20 mA,0 to 1″ w.c.
  • 668D-04-2-CDPT,0 to 10 VDC,0 to 1″ w.c.
  • 668D-04-3-CDPT,0 to 5 VDC,0 to 1″ w.c.
  • 668D-05-1-CDPT,4 to 20 mA,0 to 2.5″ w.c.
  • 668D-05-2-CDPT,0 to 10 VDC,0 to 2.5″ w.c.
  • 668D-05-3-CDPT,0 to 5 VDC,0 to 2.5″ w.c.
  • 668D-06-1-CDPT,4 to 20 mA,0 to 5″ w.c.
  • 668D-06-2-CDPT,0 to 10 VDC,0 to 5″ w.c.
  • 668D-06-3-CDPT,0 to 5 VDC,0 to 5″ w.c.
  • 668D-07-1-CDPT,4 to 20 mA,0 to 10″ w.c.
  • 668D-08-1-CDPT,4 to 20 mA,0 to 25″ w.c.
  • 668D-09-1-CDPT,4 to 20 mA,0 to 50″ w.c.
  • 668D-10-1-CDPT,4 to 20 mA,0 to 100″ w.c.
  • 668D-12-1-CDPT,4 to 20 mA,0 to ±0.1″ w.c.
  • 668D-12-2-CDPT,0 to 10 VDC,0 to ±0.1″ w.c.
  • 668D-12-3-CDPT,0 to 5 VDC,0 to ±0.1″ w.c.
  • 668D-13-1-CDPT,4 to 20 mA,0 to ±0.25″ w.c.
  • 668D-13-3-CDPT,0 to 5 VDC,0 to ±0.25″ w.c.
  • 668D-14-1-CDPT,4 to 20 mA,0 to ±0.5″ w.c.
  • 668D-15-1-CDPT,4 to 20 mA,0 to ±1″ w.c.
  • 668D-16-1-CDPT,4 to 20 mA,0 to ±2.5″ w.c.
  • 668D-17-1-CDPT,4 to 20 mA,0 to ±5″ w.c.
  • 668D-18-1-CDPT,4 to 20 mA,0 to ±10″ w.c.
  • 668D-19-1-CDPT,4 to 20 mA,0 to ±25″ w.c.
  • 668D-21-1-CDPT,4 to 20 mA,0 to 0.2″ w.c.
  • 668D-22-1-CDPT,4 to 20 mA,0 to 0.4″ w.c.
  • 668D-22-2-CDPT,0 to 10 VDC,0 to 0.4″ w.c.
  • 668D-22-3-CDPT,0 to 5 VDC,0 to 0.4″ w.c.
 

Digital Differential Pressure Gauge A4 – Sensocon

Digital Differential Pressure Control – Series A4

 
BrandSensocon
Accuracy1.00%
Media CompatibilityAir and compatible non combustible, non corrosive gasses
Maximum Pressure2 psi
Thermal Effect+/- 0.012% FS/ DegreeF
Output Signal4-20 mA (option)
Operating-10 Degree to 140 DegreeF (-23 Degree to 60 DegreeC)

The Series A4 digital differential pressure controller is a patented microprocessor based pressure controller for positive, negative, and differential pressure as well as velocity and flow. The Series A4 differential pressure controller includes (2) 8A SPDT relays and an associated programming menu that allows full configuration of variables such as setpoints, dead band, engineering units, flow coefficients, and more. The programming is done from a user friendly menu on the OLED display or uploaded using an Opti-Link™ programming key. The OLED also displays the exact setpoints or other user defined variables during normal operation. Furthermore, the menu structure can be customized by moving variables to different menu levels to accommodate many applications. Compared to other mechanical products, the Series A4 digital differential pressure controller has a significantly reduced depth, an improved look, and better performance at a similar price.
 

A3 Digital Differential Pressure Gauge – Sensocon

Series A3 Digital Differential Pressure Gauges

 
BrandSensocon
Model No.Series A3
Media CompatibilityAir and compatible non combustible, non corrosive gasses
Maximum Pressure2 psi
Thermal Effect+/- 0.012% FS/degF
Output Signal4-20 mA
Loop Resistance750 Q max
Response Time100 ms

The series A3 is a patent pending microprocessor based controller for positive, negative, and differential pressure as well as velocity and flow. The Series A3 includes (2) 8A SPDT relays and an associated software package that allows full configuration of variables such as setpoints, dead band, engineering units, flow coefficients, and more. The programming is done from a user friendly menu on the LCD display or uploaded using an Opti Link™ programming key. The LCD also displays the exact setpoints or other user defined variables during normal operation. Furthermore, the menu structure can be customized by moving variables to different menu levels to accommodate many applications. Compared to other mechanical products, the Series A3 has a significantly reduced depth, an improved look, and better performance at a lower price

 

Series 2000 Magnehelic Differential Pressure Gauge

Series 2000 Magnehelic Differential Pressure Gauge

 
BrandDWYER
Measuring Range0-50 mm WC
Model Name/NumberSeries 2000
Usage/ApplicationIndustrial
MaterialSteel
Scale Range0-100 MM WC
Accuracy+/-2.5%
Dial ShapeRound


Select The Series 2000 Magnehelic® Gage for a versatile low differential pressure gage with a wide choice of 81 models and 27 options to choose from. Using Dwyer’s simple, frictionless Magnehelic® gage movement, it quickly indicates air or noncorrosive gas pressures–either positive, negative (vacuum) or differential. The design resists shock, vibration, over-pressures and is weatherproof to IP67. Select the -HA High Accuracy Magnehelic® Gage option for an accuracy within 1% of full scale, located below in the Product Configurator. Also included with the –HA option at no extra cost are a mirrored scale overlay and a 6 point calibration certificate.

 

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.


Product Applications

  • Filter Monitoring
  • Air Velocity with Dwyer Pitot Tube
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

Dwyer Instruments Distributors in Delhi

Dwyer Instruments 2000-250PA-ASF

 
Model Number2000-250PA-ASF
Accuracy+-2%
Temperature20 to 140 DegreeF* (-6.67 to 60 DegreeC).
Weight1 lb 2 oz (510 g)
Size4″ (101.6 mm) diameter dial face.
Pressure Limits-20 in hg

Select the Magnehelic gage for high accuracy–guaranteed within 2% of full scale–and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer’s simple, frictionless Magnehelic gage movement, it quickly indicates low air or non-corrosive gas pressures–either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It’s inexpensive, too. The Magnehelic gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment

Product Highlights:
  • Bezel provides flange for flush mounting in panel.
  • Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.
  • Precision litho-printed scale is accurate and easy to read.
  • Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.
  • Pointer stops of molded rubber prevent pointer over-travel without damage.
  • “Wishbone” assembly provides mounting for helix, helix bearings and pointer shaft.
  • Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.
  • Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.
  • Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.
  • Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.
  • Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.
  • Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test.
  • Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.

Overpressure Protection:

Blowout plug is comprised of a rubber plug on the rear which functions as a relief valve by unseating and venting the gage interior when over pressure reaches approximately 25 PSIg (1.7 bar). To provide a free path for pressure relief, there are four spacer pads which maintain 0.023″ clearance when gage is surface mounted. Do not obstruct the gap created by these pads. The blowout plug is not used on models above 180″ of water pressure, medium or high pressure models, or on gages which require an elastomer other than silicone for the diaphragm. The blowout plug should not be used as a system overpressure control. High supply pressures may still cause the gage to fail due to over pressurization, resulting in property damage or serious injury. Good engineering practices should be utilized to prevent your system from exceeding the ratings or any component.

 

O-ring seal for cover assures pressure integrity of case. Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.

 

Differential Pressure Transmitters DPT30-R8 Series

Sensocon USA Series DPT30-R8 Range Differential Pressure Transmitter

 
Response Time0.8 – 4.0, jumper selectable
Maximum Pressure100 in w.c.
Power Supply24 VDC or VAC, +/- 10%
Enclosure RatingIP 54/ NEMA 3
Display3 1/2 Digit LCD Backlit LCD
Media CompatibilityDry air or non-aggressive gases

The Series DPT Multi-Range Differential Pressure Transmitter was designed specifically for the building automation and HVAC industry. With field selectable ranges down to 0.1 inches w.c., this product is ideal for monitoring building pressure, static pressure, differential pressure, or air velocity and flow. The Series DPT Differential Pressure Transmitter also has jumper selectable outputs for 4-20 mA or 0-10 V and unit selection giving additional flexibility. For a virtually maintenance free transmitter, order the optional automatic zero and the transmitter will perform its own zero point maintenance. The Multi-Range Differential Pressure Transmitter also has an optional backlit LCD for giving local indication.

Specification:

  • Maximum Pressure:100 in w.c.Media compatibility:Dry air or non-aggressive gases Accuracy:Ranges < 0.5 in w.c. = +/- 0.01 in w.c.Ranges ≥ 0.5 in w.c. = +/- 1.5%includes thermal effects, linearity, hysteresis,repeatability, and long term stability.Temperature Ranges:Compensated: 14° to 122°F Operating: 14° to 122°F
  • Response Time:0.8 – 4.0, jumper selectable Power Supply:24 VDC or VAC, +/- 10%Output:Voltage: 3-wire 0 – 10V or 0 – 5V, jumper selectable Power Consumption: <1.0WMinimum Resistance: 1kΩCurrent: 3-wire4 – 20mAPower Consumption: <1.2WMaximum Load: 500ΩEnclosure Rating:IP 54/ NEMA 3Display:3 ½” Digit LCD Backlit LCD
  • Electrical Connections:Screw terminal block

Model Number:
DPT30-R8         
inWC  -5.0 – 5.0 -10.0 – 10.0-15.0 – 15.0 0 – 10 0 – 15 0 – 20 0 – 25 0 – 30 
 Pa -1250 – 1250 -2500 – 2500 -3750 – 3750  0 – 2500 00 – 3750 0 – 5000 0 – 6250 0 – 7500 
mbar  -12.5 – 12.5 -25 – 25 -37.5 – 37.5 0 – 25 0 – 37.5  0 – 500 – 62.5  0 – 75 
mmWC -127 – 127 -254 – 254 -380 – 380   0 – 2540 – 3800 – 508 0 – 635 0 – 762 
 

Differential Pressure Transmitter DPT10-R8 SERIES

Sensocon USA Series DPT10-R8 Range Differential Pressure Transmitter

 
BrandSensocon
Response Time0.8 – 4.0, jumper selectable
Maximum Pressure100 in w.c.
Power Supply24 VDC or VAC, +/- 10%
Display3 1/2 Digit LCD Backlit LCD
Enclosure RatingIP 54/ NEMA 3
Minimum Resistance1kOhm


The Series DPT Multi-Range Differential Pressure Transmitter was designed specifically for the building automation and HVAC industry. With field selectable ranges down to 0.1 inches w.c., this product is ideal for monitoring building pressure, static pressure, differential pressure, or air velocity and flow. The Series DPT Differential Pressure Transmitter also has jumper selectable outputs for 4-20 mA or 0-10 V and unit selection giving additional flexibility. For a virtually maintenance free transmitter, order the optional automatic zero and the transmitter will perform its own zero point maintenance. The Multi-Range Differential Pressure Transmitter also has an optional backlit LCD for giving local indication.

Specification:

  • Maximum Pressure:100 in w.c.Media compatibility:Dry air or non-aggressive gasesAccuracy:Ranges < 0.5 in w.c. = +/- 0.01 in w.c.Ranges ≥ 0.5 in w.c. = +/- 1.5%includes thermal effects, linearity, hysteresis,repeatability, and long term stability.Temperature Ranges:Compensated: 14° to 122°FOperating: 14° to 122°F
  • Response Time:0.8 – 4.0, jumper selectablePower Supply:24 VDC or VAC, +/- 10%Output:Voltage: 3-wire 0 – 10V or 0 – 5V, jumper selectablePower Consumption: <1.0WMinimum Resistance: 1kΩCurrent: 3-wire4 – 20mAPower Consumption: <1.2WMaximum Load: 500ΩEnclosure Rating:IP 54/ NEMA 3Display:3 ½” Digit LCD Backlit LCD
  • Electrical Connections:Screw terminal block


Model Number:

DPT10-R8         
 inWC-0.5 – 0.5 -2.5 – 2.5 -5.0 – 5.0 0 – 0.5  0 – 1.00 – 2.5 0 – 5.0  0 – 10.0
Pa -125 – 125 -622 – 622 -1250 – 1250  0 – 125 0 – 2500 – 622 0 – 1250 0 – 2500 
mbar  -1.25 – 1.25 -6.2 – 6.2 – -12.5 – 12.5 0 – 1.25 0 – 2.5 0 – 6.2 0 – 12.5 0 – 25 
 mmWC-12.7 – 12.7 -64 – 64 -127 – 127 0 – 12.7 0 – 25.4  0 – 64 0 – 127  0 – 254

Bourdon Type Pressure Gauge

H Guru Bourdon Pressure Gauge

 
Minimum Order Quantity12 Number
Dial Size2.5 inch / 63 mm
BrandH Guru
Pressure Range0 to 4 bar(0 to 60 psi)
UseHVAC Systems
Display TypeAnalog
Pressure TypeGauge Pressure
Connection TypeBSP
Connection Size1/4 inch
Dial TypeDry
Liquid FillingGlycerine
MountingBottom
Material of casingStainless Steel
Model Name/NumberH Guru Bourdon Pressure Gauge
Wetted PartsStainless Steel
Country of OriginMade in India

H Guru Bourdon Type Pressure Gauge

MODEL -PB

MACK – H. GURU INDIA

SIZE – 2.5′,4′,6′

ACC. – 2%

CONN. – BCPM

MNTG- 1/4′, 3/8′ BSP

RANGE – 4.2/60

Bourdon Type Pressure Gauge

 
Minimum Order Quantity12 Number
Dial Size2.5 inch / 63 mm
BrandH Guru
Pressure Range0 to 4 bar(0 to 60 psi)
UseHVAC Systems
Display TypeAnalog
Pressure TypeGauge Pressure
Connection TypeBSP
Connection Size1/4 inch
Dial TypeDry
Liquid FillingGlycerine
MountingBottom
Material of casingStainless Steel
Model Name/NumberBourdon Type Pressure Gauge
Country of OriginMade in India

Bourdon Type Pressure Gauge

  • MODEL -PB
  • MACK – H. GURU INDIA
  • SIZE – 2.5′,4”,6”
  • ACC. – 2%
  • CONN. – BCPM
  • MNTG- 1/4′, 3/8” BSP
  • RANGE – 4.2/60
 

Humidity and Temperature Sensors

The Inexpensive Transmitter

 
Voltage0…1/5/10 VDC
Response Time4 s
Supply Voltage12…28 VAC / 15…40 VDC
HousingABS
IPIP65
Current4-20 mA
Output NumberTwo freely scalable analog outputs


Backed with immense experience and understanding, we are recognized as one of the most prominent importers and exporters of Transmitter that offers stable and reliable Humidity and Temperature measurement. Be it in international or domestic market, our given Transmitters are cherished and acknowledged over the global platform. The entire array of Transmitter is checked upon a series of norms so as to assure its quality. Besides, we offer the Transmitter in a huge array of stipulations as per the requirements of our patrons.

 

Technical Information :

The HygroFlex1 series is the latest development in inexpensive HVAC transmitters for relative Humidity and Temperature. The devices are equipped with the tried-and-tested Hygromer® IN-1 sensor and boast unbeatable value for money. The optional ROTRONIC SW21 Software enables you to scale, calibrate and adjust (only Humidity) the Transmitter.

Technical Specification :

General

Transmitter type

2-wire type: HF120
3/4 wire type: HF13x

Supply voltage

12…28 VAC / 15…40 VDC

Current consumption

2-wire type max. 40mA
3/4 wire type
with voltage output: < 15 mA
with current output: < 55 mA

Parameters

Humidity and/or temperature

Housing material / IP

ABS / IP65

Weight

Wall version type W and A: 140 g
Duct version 100 mm type B and D: 140 g
Duct version 300 mm type E and F: 200 g
Space version type L and S: 90 g

Integrated sensors

Yes

Operating and measurement range

-20…50oC / 0…100 %RH (non-condensing)

CE / EMC compatibility

2004/108/EC

Humidity Measurement

Humidity sensor

ROTRONIC Hygromer® IN-1

Accuracy at 23 oC +5 K

<3 %RH (10…90 %RH)

Long-term stability

<1.5 %RH per year

Response time τ63

30 s (63 % of a jump 35…80 %RH) without ???lter

Temperature Measurement

Sensor

Thermistor

Standard temperature scale

0…50oC or 0…100oF

Accuracy at 23oC +5 K

+ 0.3oK (0…50oC)

Response time

4s

Outputs

 

Number

Two freely scalable analog outputs

Current

4…20 mA

Voltage

0…1/5/10 VDC

Air Velocity and Temperature Transmitter EE75 Series

 
Output Value0 – 10 V or 4 – 20 mA (Adjustable by jumpers)
Accuracy+/- 0.2m/s 3% mv
Model NumberEE75 Series
TypeTransmitter
Measuring RangeUp to 40 m/s
Working Temperature40 to 120 deg C

Our Air Velocity Transmitters EE75 Series has a huge demand in the market due to its sturdy construction and high efficiency. These products are widely appreciated among our clients and we provide them in different specifications as per the requirement. Our Air Velocity EE75 Series is extensively used in numerous industries for diverse applications. We also offer them in various customizations to meet the different customer demands. The EE75 Series Air Velocity Transmitters were developed to obtain accurate measuring results over a wide range of Velocities and Temperatures. A high-quality hot film sensor element based on cutting- edge thin film technology ensures maximum sensitivity, even at lowest mass flows. At the same time, the innovative probe design produces reliable measuring results at high flow velocities of up to 40m/s (8000fVmin). The integrated Temperature compensation minimizes the Temperature cross-sensitivity of the EE75 Series which, combined with the robust mechanical design, allows it to be used at process Temperatures between -40 to 120°C(-40 to 248°F).

Other Details:

  • In addition to Air Velocity and Temperature values, the Transmitter calculates the volumetric flow rate in m3/h or ft3/min. The cross section of the duct needs to be determined for this purpose and the volumetric flow rate can be displayed and directed to one of the analogue outputs. The EE75 Series can be used to measure the velocity of other gases as well, although a correction has to be applied to the unit at the factory.
 

Series 605 Magnehelic Differential Pressure Indicating Transmitter Wholesaler

Series 605 Magnehelic Differential Pressure Indicating Transmitter

 
Usage/ApplicationMonitor Pressures in Ducts, Rooms,or Total Building Pressures, Filter Monitoring, Local indication of Clean Room Pressures With Process Signal sent to Control Room
BrandDWYER
Model Name/NumberSeries 605
Connection1/8″ female NPT.
Dial Size4″ (101.6 mm) dial face,5″ (127 mm) OD x 2-11/16″ (68.3 mm).
OptionalAir and non-combustible,compatible gases.

The Series 605 Magnehelic Indicating Transmitter provides for both visual monitoring and electronic control of very low differential pressure.The Series 605 is ideal for control applications in building HVAC systems where local indication is desired during routine maintenance checks or necessary when trouble shooting the system.The easily read dial gage is complimented by the two-wire, 4 to 20 mA control signal utilizing the time-proven Dwyer Magnehelic gage mechanical design and Series 600 transmitter technology. The two-wire design with terminal strip on the rear simplifies connection in any 4 to 20 mA control loop powered by a 10 to 35 VDC supply.

Product Applications
:
  • Monitor Pressures in Ducts,
  • Rooms,or Total Building Pressures,
  • Filter Monitoring,
  • Local indication of Clean Room Pressures With Process Signal sent to Control Room

Models & Ordering:
  • Model-605-0
  • Range – 0-.50″ w.c.,max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±3% mechanical accuracy.
  • Model-605-00N
  • Range – .05-0-0.2″ w.c.,max.pressure 25 psi (1.7 bar),±2% electrical accuracy,±4% mechanical accuracy.
  • Model-605-1
  • Range – 0-1.0″ w.c.,max.pressure 25 psi (1.7 bar), ±2% electrical accuracy,±2% mechanical accuracy.
  • Model-605-10 
  • Range – 0-10″ w.c.,max.pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-11
  • Range – .25-0-.25″ w.c.,max. pressure 25 psi (1.7 bar),±2% electrical accuracy,±3% mechanical accuracy.
  • Model-605-125PA
  • Range – 0-125 Pa,max.pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±3% mechanical accuracy.
  • Model-605-2
  • Range – 0-2.0″ w.c.,max. pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-20
  • Range – 0-20″ w.c.,max.pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-250PA
  • Range – 0-250 Pa,max.pressure 25 psi (1.7 bar), ±2% electrical accuracy,±2% mechanical accuracy.
  • Model-605-3
  • Range – 0-3.0″ w.c.,max.pressure 2 psi (13.79 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-30
  • Range – 0-30″ w.c.,max. pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-50
  • Range – 0-50″ w.c.,max. pressure 11 psi (75.8 kPa), ±0.5% electrical accuracy, ±2% mechanical accuracy.
  • Model-605-500PA
  • Range – 0-500 Pa,max. pressure 2 psi (13.79 kPa),±0.5% electrical accuracy,±2% mechanical accuracy.
  • Model-605-6 
  • Range – 0-6.0″ w.c.,max. pressure 2 psi (13.79 kPa),±0.5% electrical accuracy, ±2% mechanical accuracy.
  • Model-605-60PA 
  • Range – 0-60 Pa, max. pressure 25 psi (1.7 bar), ±2% electrical accuracy, ±4% mechanical accuracy.
 

Dwyer 605-0 Magnehelic Differential Pressure Indicating Transmitter 0-.50 Inch

 
Usage/ApplicationMonitor Pressures in Ducts, Rooms,or Total Building Pressures, Filter Monitoring, Local indication of Clean Room Pressures With Process Signal sent to Control Room
BrandDWYER
Model Name/NumberDwyer 605-0
Power Supply10 to 35 VDC (2-wire)
Range0-.50 Inch
ApplicationsMonitor Pressures in Ducts,Rooms,or Total Building Pressures,Filter Monitoring,Local indication o
Dial Size4″ (101.6 mm) dial face,5″ (127 mm) OD x 2-11/16″ (68.3 mm)
Size4 INCH AND 101.6 mm
Weight1 lb,12.6 oz (811 g)


Dwyer 605-0 Magnehelic Differential Pressure Indicating Transmitter 0-.50 Inch

  • Model: 605-0

Provides for both visual monitoring and electronic control of very low differential pressure. Ideal for control applications in building HVAC/R systems where local indication is desired during routine maintenance checks or necessary when trouble shooting the system.

Dwyer 605-0 MAGNEHELIC, INDICATING TRANSMITTER, 0-.50

  • Easy to read dial gauge is complimented by the two-wire, 4-20 mA control signal utilizing the time-proven Dwyer® Magnehelic® gauge mechanical design and Series 600 transmitter technology.
  • The two-wire design with terminal strip on the rear simplifies connection in any 4-20 mA control loop powered by a 10-35 VDC supply.

Gauge Specifications:

  • Service: Air and non-combustible, compatible gases.
  • Accuracy: +/-3%.
  • Stability: ±1% F.S./yr.
  • Pressure Limits: 25 psi (1.7 bar).
  • Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).
  • Process Connections: 1/8″ female NPT.
  • Size: 4″ (101.6 mm) dial face, 5″ (127 mm) O.D.x 2-11/16″ (68.3 mm).
  • Weight: 1 lb, 12.6 oz (811 g).
  • Agency Approvals: CE.

Transmitter Specifications:

  • Accuracy: +/-2% (includes linearity, hysteresis, repeatability).
  • Temperature Limits: 20 to 120°F(-6.67 to 48.9°C).
  • Compensated Temperature Range: 32 to 120°F (0 to 48.9°C).
  • Thermal Effect: ±0.025% F.S./°F (0.045% F.S./°C).
  • Power Requirements: 10-35 VDC (2-wire).
  • Output Signal: 4 to 20 mA.
  • Zero and Span Adjustments: Protected potentiometers.
  • Loop Resistance: DC; 0-1250 ohms maximum.
  • Current Consumption: DC; 38 mA maximum.
  • Electrical Connections: Screw terminal block.
  • Mounting Orientation: Diaphragm in vertical position.


Dwyer 605-0 Specifications

Gauge
ServiceAir and non-combustible, compatible gases
Stability±1% FS/yr
Temperature Limits20 to 120°F (-6.67 to 48.9°C)
Process Connections???” female NPT
Size4″ (101.6 mm) dial face, 5″ (127 mm) OD x 2-11/16″ (68.3 mm)
Weight1 lb, 12.6 oz (811 g)
Agency ApprovalsCE
Transmitter
Temperature Limits20 to 120°F (-6.67 to 48.9°C)
Compensated Temperature Range32 to 120°F (0 to 48.9°C)
Thermal Effect±0.025% FS/°F (0.045% FS/°C)
Power Requirements10 to 35 VDC (2-wire)
Output Signal4 to 20 mA
Zero and Span AdjustmentsProtected potentiometers
Loop ResistanceDC: 0 to 1250 Ω maximum
Current ConsumptionDC: 38 mA maximum
Electrical ConnectionsScrew terminal block
Mounting OrientationDiaphragm in vertical position