Sensocon USA Series DPT30-R8 Range Differential Pressure Transmitter
Response Time
0.8 – 4.0, jumper selectable
Maximum Pressure
100 in w.c.
Power Supply
24 VDC or VAC, +/- 10%
Enclosure Rating
IP 54/ NEMA 3
Display
3 1/2 Digit LCD Backlit LCD
Media Compatibility
Dry air or non-aggressive gases
The Series DPT Multi-Range Differential Pressure Transmitter was designed specifically for the building automation and HVAC industry. With field selectable ranges down to 0.1 inches w.c., this product is ideal for monitoring building pressure, static pressure, differential pressure, or air velocity and flow. The Series DPT Differential Pressure Transmitter also has jumper selectable outputs for 4-20 mA or 0-10 V and unit selection giving additional flexibility. For a virtually maintenance free transmitter, order the optional automatic zero and the transmitter will perform its own zero point maintenance. The Multi-Range Differential Pressure Transmitter also has an optional backlit LCD for giving local indication.
Specification:
Maximum Pressure:100 in w.c.Media compatibility:Dry air or non-aggressive gases Accuracy:Ranges < 0.5 in w.c. = +/- 0.01 in w.c.Ranges ≥ 0.5 in w.c. = +/- 1.5%includes thermal effects, linearity, hysteresis,repeatability, and long term stability.Temperature Ranges:Compensated: 14° to 122°F Operating: 14° to 122°F
Response Time:0.8 – 4.0, jumper selectable Power Supply:24 VDC or VAC, +/- 10%Output:Voltage: 3-wire 0 – 10V or 0 – 5V, jumper selectable Power Consumption: <1.0WMinimum Resistance: 1kΩCurrent: 3-wire4 – 20mAPower Consumption: <1.2WMaximum Load: 500ΩEnclosure Rating:IP 54/ NEMA 3Display:3 ½” Digit LCD Backlit LCD
Sensocon USA Series DPT10-R8 Range Differential Pressure Transmitter
Brand
Sensocon
Response Time
0.8 – 4.0, jumper selectable
Maximum Pressure
100 in w.c.
Power Supply
24 VDC or VAC, +/- 10%
Display
3 1/2 Digit LCD Backlit LCD
Enclosure Rating
IP 54/ NEMA 3
Minimum Resistance
1kOhm
The Series DPT Multi-Range Differential Pressure Transmitter was designed specifically for the building automation and HVAC industry. With field selectable ranges down to 0.1 inches w.c., this product is ideal for monitoring building pressure, static pressure, differential pressure, or air velocity and flow. The Series DPT Differential Pressure Transmitter also has jumper selectable outputs for 4-20 mA or 0-10 V and unit selection giving additional flexibility. For a virtually maintenance free transmitter, order the optional automatic zero and the transmitter will perform its own zero point maintenance. The Multi-Range Differential Pressure Transmitter also has an optional backlit LCD for giving local indication.
Specification:
Maximum Pressure:100 in w.c.Media compatibility:Dry air or non-aggressive gasesAccuracy:Ranges < 0.5 in w.c. = +/- 0.01 in w.c.Ranges ≥ 0.5 in w.c. = +/- 1.5%includes thermal effects, linearity, hysteresis,repeatability, and long term stability.Temperature Ranges:Compensated: 14° to 122°FOperating: 14° to 122°F
Backed with immense experience and understanding, we are recognized as one of the most prominent importers and exporters of Transmitter that offers stable and reliable Humidity and Temperature measurement. Be it in international or domestic market, our given Transmitters are cherished and acknowledged over the global platform. The entire array of Transmitter is checked upon a series of norms so as to assure its quality. Besides, we offer the Transmitter in a huge array of stipulations as per the requirements of our patrons.
Technical Information :
The HygroFlex1 series is the latest development in inexpensive HVAC transmitters for relative Humidity and Temperature. The devices are equipped with the tried-and-tested Hygromer® IN-1 sensor and boast unbeatable value for money. The optional ROTRONIC SW21 Software enables you to scale, calibrate and adjust (only Humidity) the Transmitter.
Technical Specification :
General
Transmitter type
2-wire type: HF120 3/4 wire type: HF13x
Supply voltage
12…28 VAC / 15…40 VDC
Current consumption
2-wire type max. 40mA 3/4 wire type with voltage output: < 15 mA with current output: < 55 mA
Parameters
Humidity and/or temperature
Housing material / IP
ABS / IP65
Weight
Wall version type W and A: 140 g Duct version 100 mm type B and D: 140 g Duct version 300 mm type E and F: 200 g Space version type L and S: 90 g
Integrated sensors
Yes
Operating and measurement range
-20…50oC / 0…100 %RH (non-condensing)
CE / EMC compatibility
2004/108/EC
Humidity Measurement
Humidity sensor
ROTRONIC Hygromer® IN-1
Accuracy at 23 oC +5 K
<3 %RH (10…90 %RH)
Long-term stability
<1.5 %RH per year
Response time τ63
30 s (63 % of a jump 35…80 %RH) without ???lter
Temperature Measurement
Sensor
Thermistor
Standard temperature scale
0…50oC or 0…100oF
Accuracy at 23oC +5 K
+ 0.3oK (0…50oC)
Response time
4s
Outputs
Number
Two freely scalable analog outputs
Current
4…20 mA
Voltage
0…1/5/10 VDC
Air Velocity and Temperature Transmitter EE75 Series
Output Value
0 – 10 V or 4 – 20 mA (Adjustable by jumpers)
Accuracy
+/- 0.2m/s 3% mv
Model Number
EE75 Series
Type
Transmitter
Measuring Range
Up to 40 m/s
Working Temperature
40 to 120 deg C
Our Air Velocity Transmitters EE75 Series has a huge demand in the market due to its sturdy construction and high efficiency. These products are widely appreciated among our clients and we provide them in different specifications as per the requirement. Our Air Velocity EE75 Series is extensively used in numerous industries for diverse applications. We also offer them in various customizations to meet the different customer demands. The EE75 Series Air Velocity Transmitters were developed to obtain accurate measuring results over a wide range of Velocities and Temperatures. A high-quality hot film sensor element based on cutting- edge thin film technology ensures maximum sensitivity, even at lowest mass flows. At the same time, the innovative probe design produces reliable measuring results at high flow velocities of up to 40m/s (8000fVmin). The integrated Temperature compensation minimizes the Temperature cross-sensitivity of the EE75 Series which, combined with the robust mechanical design, allows it to be used at process Temperatures between -40 to 120°C(-40 to 248°F).
Other Details:
In addition to Air Velocity and Temperature values, the Transmitter calculates the volumetric flow rate in m3/h or ft3/min. The cross section of the duct needs to be determined for this purpose and the volumetric flow rate can be displayed and directed to one of the analogue outputs. The EE75 Series can be used to measure the velocity of other gases as well, although a correction has to be applied to the unit at the factory.
Series 605 Magnehelic Differential Pressure Indicating Transmitter
Usage/Application
Monitor Pressures in Ducts, Rooms,or Total Building Pressures, Filter Monitoring, Local indication of Clean Room Pressures With Process Signal sent to Control Room
Brand
DWYER
Model Name/Number
Series 605
Connection
1/8″ female NPT.
Dial Size
4″ (101.6 mm) dial face,5″ (127 mm) OD x 2-11/16″ (68.3 mm).
Optional
Air and non-combustible,compatible gases.
The Series 605 Magnehelic Indicating Transmitter provides for both visual monitoring and electronic control of very low differential pressure.The Series 605 is ideal for control applications in building HVAC systems where local indication is desired during routine maintenance checks or necessary when trouble shooting the system.The easily read dial gage is complimented by the two-wire, 4 to 20 mA control signal utilizing the time-proven Dwyer Magnehelic gage mechanical design and Series 600 transmitter technology. The two-wire design with terminal strip on the rear simplifies connection in any 4 to 20 mA control loop powered by a 10 to 35 VDC supply. Product Applications:
Monitor Pressures in Ducts,
Rooms,or Total Building Pressures,
Filter Monitoring,
Local indication of Clean Room Pressures With Process Signal sent to Control Room
Dwyer 605-0 Magnehelic Differential Pressure Indicating Transmitter 0-.50 Inch
Usage/Application
Monitor Pressures in Ducts, Rooms,or Total Building Pressures, Filter Monitoring, Local indication of Clean Room Pressures With Process Signal sent to Control Room
Brand
DWYER
Model Name/Number
Dwyer 605-0
Power Supply
10 to 35 VDC (2-wire)
Range
0-.50 Inch
Applications
Monitor Pressures in Ducts,Rooms,or Total Building Pressures,Filter Monitoring,Local indication o
Dial Size
4″ (101.6 mm) dial face,5″ (127 mm) OD x 2-11/16″ (68.3 mm)
Size
4 INCH AND 101.6 mm
Weight
1 lb,12.6 oz (811 g)
Dwyer 605-0 Magnehelic Differential Pressure Indicating Transmitter 0-.50 Inch
Model: 605-0
Provides for both visual monitoring and electronic control of very low differential pressure. Ideal for control applications in building HVAC/R systems where local indication is desired during routine maintenance checks or necessary when trouble shooting the system.
Easy to read dial gauge is complimented by the two-wire, 4-20 mA control signal utilizing the time-proven Dwyer® Magnehelic® gauge mechanical design and Series 600 transmitter technology.
The two-wire design with terminal strip on the rear simplifies connection in any 4-20 mA control loop powered by a 10-35 VDC supply.
Gauge Specifications:
Service: Air and non-combustible, compatible gases.
Accuracy: +/-3%.
Stability: ±1% F.S./yr.
Pressure Limits: 25 psi (1.7 bar).
Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).
100 / 250 / 1000 / 2500 PA AND +-100 Pa / +-250 / +-300 / +-500 PA
Size
89 x 86.5 x 37.1 mm
Aerosense Differential Pressure Controller Aerosense Differential Pressure Controller with field selectable measuring range for building automation in HVAC/R industry.
Features:
Unit selectable via menu i.e. PA, kPA, MM WC, IN WC, MBAR
Combines up to two relay outputs
Optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes)
The AZ-calibration eliminates all output signal drift due to thermal, electronic or mechanical effects
DPI2500-2R-D Aerosense Differential Pressure Controller Aerosense Differential Pressure Controller with field selectable measuring range for building automation in HVAC/R industry.
Features:
Unit selectable via menu i.e. PA, kPA, MM WC, IN WC, MBAR
Combines up to two relay outputs
Optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes)
The AZ-calibration eliminates all output signal drift due to thermal, electronic or mechanical effects
DPIC500-2R-D Aerosense Differential Pressure Controller Aerosense Differential Pressure Controller with field selectable measuring range for building automation in HVAC/R industry.
Features:
Unit selectable via menu i.e. PA, kPA, MM WC, IN WC, MBAR
Combines up to two relay outputs
Optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes)
The AZ-calibration eliminates all output signal drift due to thermal, electronic or mechanical effects
Demand Control Ventilation In Schools,Office Buildings,Hospitals And Other Indoor Environments
Brand
Aerosense
Measurement Range
0 to 2000/ 3000/ 5000/ 10000 ppm
Accuracy
+-30ppm +-3%
Operating Humidity Range
0 to 95% RH
Operating Temperature
-10 to 60 deg C
Power
24 VDC,AC
Size
123x70x43 mm
Storage Temperature
-30 to 70 deg C
Storage Temperature for Cold Storage
-40 to 70 deg C
Response Time
150 seconds
Response Time For Cold Storage
70 Seconds
Sampling Interval
3 Sec
CDT-100 Aerosense Carbon Dioxide TransmitterSeries CDT-100, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements. Measurement range upto 10000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.
Product Applications:
Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
RS-485 MODBUS output: (4-wired) Modicon MODBUS RTU mode, which follow Modicon Modbus protocol-settable address ID switch
Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch
Model No. CDT-100Carbon Dioxide TransmitterCDT-100-LCDCarbon Dioxide Transmitter with displayCDT-100-CSCarbon Dioxide Transmitter for cold storageCDT-100-CS-LCDCarbon Dioxide Transmitter for cold storage with display CDT-100-M Carbon Dioxide Transmitter with MODBUS Communication CDT-100-M-LCD Carbon Dioxide Transmitter with MODBUS Communication & display
CDT-100-RLY Aerosense Carbon Dioxide Transmitter
Minimum Order Quantity
1 Piece
Usage
Demand Control Ventilation In Schools,Office Buildings,Hospitals And Other Indoor Environments
Model
Series CDT-100-RLY
Size
123mmx70mmx43mm
Response Time
150 seconds
Brand
Aerosense
Operating Temperature
10 to 60 deg C
Storage temperature
-30 to 70 deg C
CDT-100-RLY Aerosense Carbon Dioxide Transmitter, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements. Measurement range 2000 ppm (5000/10000 ppm) selectable by jumper. It gives analog and Relay output and supports various functions like recalibration function.
Product Applications:
Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
Analog Voltage/Current Output: (6-wired) 0/4-20Ma or 0/2-10V- settable by switch
Models available with SPST (Single Pole, Single Throw, normally open) relay output.
Re-Calibration function: 10 minutes’ manual recalibration is executable with TRB-100 tool
CDT-300 Aerosense Carbon Dioxide Transmitter
Minimum Order Quantity
1 Piece
Model Number
Series CDT-300
Usage/Application
Demand Control Ventilation In Schools,Office Buildings,Hospitals And Other Indoor Environments
Brand
Aerosense
Size
123mmx70mmx43mm
Response Time
150 Seconds
Operating Temperature
-10 to 60 deg C
Operating Humidity range
0 to 95% RH
Storage temperature
-30 to 70 deg C
Power
24 V Dc
CDT-300 Aerosense Carbon Dioxide TransmitterSeries CDT-300, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements. Measurement range upto 70000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.
Product Applications:
Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch
13 to 36 VDC for current models, 13 to 36 VDC or 16 to 28 VAC for voltage models.
Accuracy
+-0.5 DegreeC @ 25 DegreeC.
Product Weight
5.11 oz, 145 g (duct/immersion); 8.4 oz (238 g) (OSA without radiation shield); 1 lb 7.4 oz (663.4 g
Rated Supply Voltage
Series BTT Temperature Transmitter
Response Time
100 ms.
Supply Voltage Limits
4 to 20 mA or 0 to 10 VDC (depending on model).
Output Type
4 to 20 mA or 0 to 10 VDC (depending on model).
Country of Origin
Made in India
SERIES BTT TEMPERATURE TRANSMITTERS
Current or Voltage Output; NEMA 4X Enclosures
The Series BTT Temperature Transmitters offer Transmitter output signals with the same form and fit as our popular TE Thermistor and RTD sensors for building HVAC Applications. Thermowells are required when using immersion models in liquid applications. NIST CALIBRATION Available In Product Configurator.
PRODUCT APPLICATIONS
Building Automation System Temperature Monitoring
MODELS & ORDERING Model Description
BTT-D04-1 Duct Mount Temperature Transmitter with 4 to 20 mA output, 4″ probe
BTT-D04-2 Duct Mount Temperature Transmitter with 0 to 10 V output, 4″ probe
BTT-D06-1 Duct Mount Temperature Transmitter with 4 to 20 mA output, 6″ probe
BTT-D06-2 Duct Mount Temperature Transmitter with 0 to 10 V output, 6″ probe
BTT-D08-1 Duct Mount Temperature Transmitter with 4 to 20 mA output, 8″ probe
BTT-D08-2 Duct Mount Temperature Transmitter with 0 to 10 V output, 8″ probe
BTT-D12-1 Duct Mount Temperature Transmitter with 4 to 20 mA output, 12″ probe
BTT-D12-2 Duct Mount Temperature Transmitter with 0 to 10 V output, 12″ probe
BTT-D18-1 Duct Mount Temperature Transmitter with 4 to 20 mA output, 18″ probe
BTT-D18-2 Duct Mount Temperature Transmitter with 0 to 10 V output, 18″ probe
BTT-D25-1 Duct Mount Temperature Transmitter with 4 to 20 mA output, 2.5″ probe
BTT-D25-2 Duct Mount Temperature Transmitter with 0 to 10 V output, 2.5″ probe
SPECIFICATIONS
Temperature Sensor:Pt1000 RTD.
Range:-40 to 140°F (-40 to 60°C).
Temperature Limits:Operating: -40 to 302°F (-40 to 150°C).
Accuracy:±0.5°C @ 25°C.
Thermal Effect:±0.01%/°C.
Response Time:100 ms.
Wetted Materials:All Models:304 SS (probe), polycarbonate (housing);Duct and immersion models: Neoprene (gasket); Outside air models: Nylon (insert), silicone (O-ring).
Process Connection:1/2″ NPT (immersion models only).
Electrical Connection:Removable terminal block, knocks out for conduit fitting.
Conduit Connection:1/2″ NPT.
Probe Lengths:2.5 to 18″ (depending on configuration).
Power Requirements:13 to 36 VDC for current models, 13 to 36 VDC or 16 to 28 VAC for voltage models.
Output Signal:4 to 20 mA or 0 to 10 VDC (depending on model).
Weight:5.11 oz, 145 g (duct/immersion); 8.4 oz (238 g) (OSA without radiation shield);1 lb 7.4 oz (663.4 g) (OSA with radiation shield).
Agency Approvals:CE.
FEATURES
Duct, immersion, and outside air models available
Radiation shield available for mounting in direct sunlight
Transmitter output allows for longer wire runs than standard thermistor sensors
Series BTT Temperature Transmitters Models and Ordering
Minimum Order Quantity
12 Piece
Usage/Application
Building Automation System Temperature Monitoring
Model Name/Number
SERIES BTT TEMPERATURE TRANSMITTERS
Brand
Dwyer USA
Voltage
13 to 36 VDC for current models,13 to 36 VDC or 16 to 28 VAC for voltage models.
Accuracy
+-0.5 DegreeC @ 25 DegreeC.
Product Weight
5.11 oz,145 g (duct/immersion); 8.4 oz (238 g) (OSA without radiation shield); 1 lb 7.4 oz (663.4 g
Response Time
100 ms.
Supply Voltage Limits
4 to 20 mA or 0 to 10 VDC (depending on model).
Output Type
4 to 20 mA or 0 to 10 VDC (depending on model).
Part Type
SERIES BTT TEMPERATURE TRANSMITTERS
Country of Origin
Made in India
SERIES BTT TEMPERATURE TRANSMITTERS MODELS & ORDERING
Duct Mount Temperature Transmitter
BTT-D04-1-With 4 to 20 mA output,4″ probe
BTT-D04-2-With 0 to 10 V output,4″ probe
BTT-D06-1-With 4 to 20 mA output,6″ probe
BTT-D06-2-With 0 to 10 V output,6″ probe
BTT-D08-1-With 4 to 20 mA output,8″ probe
BTT-D08-2-With 0 to 10 V output,8″ probe
BTT-D12-1-With 4 to 20 mA output,12″ probe
BTT-D12-2-With 0 to 10 V output,12″ probe
BTT-D18-1-With 4 to 20 mA output,18″ probe
BTT-D18-2-With 0 to 10 V output,18″ probe
BTT-D25-1-With 4 to 20 mA output,2.5″ probe
BTT-D25-2-With 0 to 10 V output,2.5″ probe
Immersion Temperature Transmitter
BTT-I04-1-With 4 to 20 mA output,-40 to 60 C temperature range,4″ probe
BTT-I04-2-With 0 to 10 V output,-40 to 60 C temperature range,4″ probe
BTT-I04-5-With 4 to 20 mA output,0 to 100 C temperature range,4″ probe
BTT-I04-6-With 0 to 10 V output,0 to 100 C temperature range, 4″ probe
BTT-I06-1-With 4 to 20 mA output,-40 to 60 C temperature range,6″ probe
BTT-I06-2-With 0 to 10 V output,-40 to 60 C temperature range,6″ probe
BTT-I06-5-With 4 to 20 mA output,0 to 100 C temperature range,6″ probe
BTT-I06-6-With 0 to 10 V output,0 to 100 C temperature range,6″ probe
BTT-I08-1-With 4 to 20 mA output,-40 to 60 C temperature range,8″ probe
BTT-I08-2-With 0 to 10 V output,-40 to 60 C temperature range,8″ probe
BTT-I08-5-With 4 to 20 mA output,0 to 100 C temperature range,8″ probe
BTT-I08-6-With 0 to 10 V output,0 to 100 C temperature range,8″ probe
BTT-I12-1-With 4 to 20 mA output,-40 to 60 C temperature range,12″ probe
BTT-I12-2-With 0 to 10 V output,-40 to 60 C temperature range,12″ probe
BTT-I12-5-With 4 to 20 mA output,0 to 100 C temperature range,12″ probe
BTT-I12-6-With 0 to 10 V output,0 to 100 C temperature range,12″ probe
BTT-I25-1-With 4 to 20 mA output,-40 to 60 C temperature range,2.5″ probe
BTT-I25-2-With 0 to 10 V output,-40 to 60 C temperature range,2.5″ probe
BTT-I25-5-With 4 to 20 mA output,0 to 100 C temperature range,2.5″ probe
BTT-I25-6-With 0 to 10 V output,0 to 100 C temperature range,2.5″ probe
Outside Air Temperature Transmitter
BTT-O25-1-Outside Air Temperature Transmitter with 4 to 20 mA Output
BTT-O25-2-Outside Air Temperature Transmitter with 0 to 10 V Output
BTT-R25-1-Outside Air Temperature Transmitter with 4 to 20 mA Output with solar radiation shield
BTT-R25-2- Outside Air Temperature Transmitter with 0 to 10 V Output with solar radiation shield
European Wall Mount Temperature Transmitter (BTT-E/N)
BTT-E00-3-European wall mount temperature transmitter with 4 to 20 mA output
BTT-E00-4-European wall mount temperature transmitter with 0 to 10 VDC output
BTT-N00-3-North American wall mount temperature transmitter with 4 to 20 mA output
BTT-N00-4-North American wall mount temperature transmitter with 0 to 10 VDC output
Dwyer BTT-D04-1 Duct Mount Temperature Sensors
Minimum Order Quantity
12 Piece
Usage/Application
Building Automation System Temperature Monitoring
Model Name/Number
Dwyer BTT-D04-1
Brand
Dwyer USA
Voltage
13 to 36 VDC
Accuracy
+-0.5 DegreeC @ 25 DegreeC.
Operating Range
Dwyer BTT-D04-1
Product Weight
5.11 oz (145 g)
Protection Type
Dwyer BTT-D04-1 Duct Mount Temperature Sensors
Rated Supply Voltage
13 to 36 VDC
Response Time
100 msec
Output Type
4 to 20 mA
Part Type
Dwyer BTT-D04-1 Duct Mount Temperature Sensors
Country of Origin
Made in India
Dwyer BTT-D04-1 Duct Mount Temperature Sensors
Output Signal: 4 – 20 mA,
Probe Length: 4″
Brand Dwyer Part # BTT-D04-1
Model # BTT Series
Condition Brand New
Dwyer, BTT-D04-1, BTT Series 4 – 20 mA Duct Mount Temperature Transmitter with 4″ Probe
The Series BTT Temperature Transmitter Can Be Used For The Following Applications: Monitoring The Temperature Inside Air Ducts For HVAC, Transmitting Temperature Inside Water Lines For Chillers Features
Transmitter Output Allows For Longer Wire Runs Than Standard Thermistor Sensors
Applications
Building Automation System Temperature Monitoring
Notifications
Item Is Non-Returnable Unless Defective
Declaration:
This Product Can Be Customized To Your Needs (Voltage,Ranges,Sizes,Additional Documents,Etc.). Please Contact Us Or Add To Quote If Any Specific Requirements Are Needed.
Technical Details
Temperature Sensor:Pt1000 RTD
Range:-40 to 140 °F (-40 to 60 °C)
Temperature Limits:-40 to 140 °F (-40 to 60 °C)
Accuracy:±0.5°C @ 25°C.
Response Time:100 msec
Wetted Materials:304 SS (probe), polycarbonate (housing), Neoprene (gasket)
Electrical Connection:Removable terminal block, knocks out for conduit fitting
Converts all type of Thermocouple, RTD, Ohms, mV into 4 to 20mA analogue output
Model Name/Number
GALAXY
Brand
GALAXY
Rated Supply Voltage
10 to 32 VDC
Supply Voltage Limits
10 to 32 VDC
Output Type
2 Wire, 4 to 20mA
Part Type
Universal Type Temperature Transmitter
Country of Origin
Made in India
Input Value
All type of Thermocouple, RTDs, Ohms, mV
Programming & Calibration
User friendly software and a USB Calibrator
Mounting
Head Mount
Universal Type Temperature Transmitter
PC Programmable Head Mount Temperture Transmitter Which Converts All Tc, RTD, Ohms Mv Into a Scalable Analogue Signal Of 4 to 20ma. Performance
2-Wire Technology, 4 to 20ma Analogue Output.
High Accuracy In Total Ambient Temperature Range.
Internal Cold Junction Compensation.
Wide Voltage Supply Range.
Customer Specific Measurement Range Setting Or Expanded Setup.
Simple And User Friendly Software.
USB Communication.
INPUT
Type : TC, RTD, Ohms, mV
Measurement Ranges : -200 to 850°c
Connection Type : 3-Wire Connection
OUTPUT
Output Signal : 2 Wire, 4 to 20ma Scalable Analogue Signal Output
Current Alarm Output : 3. 6ma or 22ma When Sensor Damage Or Break.
TECHNICAL SPECIFICATIONS
Damp : 0-32s
Current Limit : ≤ 22ma
Saturation Current : Low 3. 8ma ; High 20. 6ma
Response Time : ≤ 0. 8s
Data Refresh Rate : 4 Times/Sec
Accuracy : ± 0. 1%
Stability :0. 01 ??c
Power Supply : 10 to 32 VDC
Temperature Transmitters
Minimum Order Quantity
12 Number
Usage/Application
Converts RTD & Thermocouple Input into linear scalable 4 to 20mA.
Model Name/Number
TR 213
Brand
GALAXY
Voltage
24 VDC
Rated Supply Voltage
24 VDC
Output Type
2 Wire,4 to 20mA
Country of Origin
Made in India
Input Value
Universal All type of RTD & Thermocouple Input
Temperature Transmitters
TT 210 is a Head Mount Non isolated universal temperature transmitter for resistance thermometers (RTD), thermocouples (TC), resistance & voltage (mV) which converts all these data signals into scalable 4 to 20mA analogue output signal.
This is a user programmable temperature transmitter which can be programmed for input signal from ANDROID SMART PHONE or LAPTOP via data cable & user friendly operating software.
Performance Features:
2 wire technology 4 to 20 mA analogue output.
High accuracy in total ambient temperature range.
An internal temperature sensor for active temperature compensation.
Wide voltage supply range.
Customer specific measurement range setting.
Simple & user friendly software
USB Communication
Technical Data
Input RTD, TC, OHM, mV
Output 4 to 20 mA
Supply voltage 7.5 to 45 VDC
Cold junction Internal
Influence of ambient Negligible
Load influence Negligible
Power supply influence Negligible
Resolution 0.3 uA
Installation Sensor head from B
Operation PC – programmable
Weight Approx. 35 GMS
Dimensions 44 MM × 22. 5 MM (Φ × H)
RTD PT 100 Temperature Transmitter
Minimum Order Quantity
12 Piece
Usage/Application
Use for converting RTD Signal into scalable analog Input signal 4 to 20mA
Model Name/Number
RTD PT 100
Brand
GALAXY
Voltage
10 to 32 VDC
Accuracy
+- 0.1%
Protection Type
RTD PT 100 Temperature Transmitter
Output Type
4 to 20mA
Part Type
RTD PT 100 Temperature Transmitter
Country of Origin
Made in India
Programming
Can be programmed with user freindly software & USB
RTD PT 100 Temperature Transmitter
PC Programmable Head Mount Temperture Transmitter Which Converts All Tc, RTD, Ohms Mv Into a Scalable Analogue Signal Of 4 to 20ma. Performance
2-Wire Technology, 4 to 20ma Analogue Output.
High Accuracy In Total Ambient Temperature Range.
Internal Cold Junction Compensation.
Wide Voltage Supply Range.
Customer Specific Measurement Range Setting Or Expanded Setup.
Simple And User Friendly Software.
USB Communication.
INPUT
Type : TC, RTD, Ohms, mV ( RTD PT 100 )
Measurement Ranges : -200 to 850°c
Connection Type : 3-Wire Connection
OUTPUT
Output Signal : 2 Wire, 4 to 20ma Scalable Analogue Signal Output
Current Alarm Output : 3. 6ma or 22ma When Sensor Damage Or Break.