+(91)-9871034100
PHONE NO
07AOSPS8386M1ZM
GST NO

Elementor #2070


Battery Powered Temperature Indicator

Rs 2,500 / Piece

Usage/ApplicationProvides local temperature indication in areas without power availability
Weight6.0 oz (170 g).
BrandDWYER USA
ConditionNew
ModelSeries-BPI
Power Requirements3.6 V AA lithium metal battery, included, user replaceable.
Battery Life2 years.
Display0.3″ (7.6 mm) 4-digit LCD.
Resolution0.1 Degree C.
Ambient Operating Temperature14 to 158 Degree F (-10 to 70 Degree C).
Storage Temperature4 to 185 Degree F (-20 to 85 Degree C).
Front Panel ProtectionNEMA 4X (IP66).

Battery Powered Temperature Indicator

The Series BPI Battery Powered Indicator accepts RTD or Thermocouple input and provides local or remote display of temperature measurements. Quickly navigate the menu system to customize for each application. Three push buttons allow the user to select input type, engineering units (°F or °C), offset temperature, decimal point position, and password protection. The indicator is housed in a polycarbonate NEMA 4X (IP66) enclosure for additional protection from the environment.

Features:

  • Programmable input type, engineering units (°F/°C), offset temperature, decimal point position, and password protection
  • Four-digit segmented display


Applications:

  • Provides local temperature indication in areas without power availability

 

Installation:
Configuration:
Fit the battery as described in Battery section, then follow the simple configuration menus printed on the reverse side of this sheet. This procedure can be performed with or without the sensor connected. Fit the correct units legend to the front panel face.

Enclosure:
The case offers various options for sensor entry. Please refer to the data sheet for further details. The sensor may be fixed directly to the housing, or remotely connected using cable and gland. Cable length must be no greater than 20 meters to comply with CE certification. All external cabling/sensor entries must maintain IP67 rating.



Additional Information:

  • Item Code: Series-BPI
 


Digital Indicating Transmitter

Rs 8,700 / Piece

Power Requirement20 to 35 VDC.
Operating Temp-6 to 140 Degree F (-20 to 60 Degree C)
ApplicationElectrically isolates pressure and level transmitters from unregulated circuits for intrinsically sa
ApplicationsElectrically isolates pressure and level transmitters from unregulated circuits for intrinsically sa
ConditionNew
BrandDWYER USA
Humidity5 to 95% RH.
Storage Temperature-40 to 176 Degree F (-40 to 80 Degree C).
Model NumberSeries-MTL5541
Automation GradeManual
Weight150 g.
LED IndicatorGreen Power Indication.

Digital Indicating Transmitter

The SERIES MTL5541 Galvanic Barrier provides intrinsically safe isolation for communication with Dwyer® transmitters approved for use in hazardous areas. This galvanic barrier eliminates the need for a high integrity earth ground required when using shunt type diode type safety barriers. DIN rail mounting and plug-in signal and power connectors simplify installation and maintenance.

Features:

  • Designed to mount on most standard DIN rails
  • Approved for use in hazardous areas


Specification:

  • Hazardous Area Input : Signal range: 0 to 24 mA (including over-range); Transmitter voltage: 16.5 V at 20 mA.
  • Safe Area Output : Signal range: 4 to 20 mA; Under/over-range: 0 to 24 mA;Load resistance: 0 to 360Ω @ 24 mA, or 0 to 450Ω @ 20 mA; Current sink: 600Ω max.; Maximum Voltage Source: 24 VDC; Output resistance: > 1 MΩ.
  • Response Time : Settles to within 10% of final value within 50 µs.
  • Current Consumption (20 mA signal) : 51 mA @ 24V.
  • Maximum Power Dissipation (20 mA signal) : 0.7 W @ 24 VDC, 1.0 W @ 24 VDC.
  • Isolation : 250 V RMS, tested at 1500 V RMS minimum, between safe- and hazardous-area terminals; 50 V between safe-area circuits and power supply.
  • Transfer Accuracy at 68°F (20°C) : Better than 15 µA.
  • Temperature Drift : < 0.8µA/°C.
  • Mounting : T-section 35mm DIN rail (7.5 or 15mm) to EN 50022.
  • Terminals : Accommodate up to 2.5 mm2 stranded or single-core.
  • Safety Description : Vo= 28 V, Io= 93 mA, Po= 651mW, Um= 253 RMS or DC.


Applications:

  • Electrically isolates pressure and level transmitters from unregulated circuits for intrinsically safe applications



Additional Information:

  • Item Code: Series-MTL5541
 


Indicating Alarm Annunciator

Rs 2,650 / Piece

Usage/ApplicationTank level monitoring
Model No.Series-AN2
BrandDWYER USA
Weight9.6 oz (272 g).
ApplicationWater and wastewater panels
Ambient Operating Temperature-40 to 149 Degree F (-40 to 65 Degree C).
Mounting1/8 DIN.
Housing MaterialUL rated 94V-0 high impact plastic.
Enclosure RatingNEMA 4X (IP65) front panel.
Power Consumption20 W (6 W on low voltage models).

Indicating Alarm Annunciator

The Series AN2 Indicating Alarm Annunciator provides visible and audible alarms for up to eight inputs. The annunciator also has two SPDT relay outputs that can be used to initiate external alarms, buzzers, or paging devices. The Integral 24 VDC power supply can power most level, temperature, pressure, and flow switches. Audible alarm conditions can be acknowledged, reset, or silenced either via the front panel push buttons or the rear terminal block. The Series AN2 can be set to any common ISA sequences including First-Out.

Features: 

  • Includes integral 24 VDC power supply to power most switches
  • Can be set to any common ISA sequences


Specification:

  • Inputs : NO or NC switches, Open Collector Transistor (Open circuit voltage = 3.3 VDC); Logic Levels: LO = 0 to 0.9 VDC, HI = 2.4 to 28 VDC (100 KΩ input impedance).
  • Outputs : Two SPDT relay (3 A @ 250 VAC or 30 VDC, resistive; 1/14 HP @ 125/250 VAC, inductive).
  • Power Requirements : 85 to 265 VAC 50/60 Hz, 90 to 265 VDC; 12 to 36 VDC, 12 to 24 VAC (depending on model).


Applications:

  • Water and wastewater panels
  • Tank level monitoring
  • Temperature monitoring process

Other Details:

ModelNumber of OutputsPower Supply
AN24-1485 to 265 VAC
AN24-2412 to 36 VDC
AN28-1885 to 265 VAC
AN28-2812 to 36 VDC

 




Additional Information:

  • Item Code: Series-AN2

 

 


Miniature Current Switch

Rs 6,400 / Piece

Weight0.5 oz (14.5 g).
ApplicationBAS
Model No.Series-MCS
BrandDWYER USA
Amperage RangeMCS-111050 0.5 to 50 A AC continuous; MCS-111001 0.01 to 1 A AC continuous.
Output RatingIsolated, N.O. 0.3 A 130 V DC/AC.
Hysteresis1%.
Response Time200 ms.
Temperature Limits32 to 122 Degree F (0 to 50 Degree C).
Humidity10 to 95% RH (non-condensing).
Enclosure RatingUL 94V-0 flammability rated ABS, insulation class 600 V.

Miniature Current Switch

The SERIES MCS Miniature Current Switches are ideal for monitoring the current usage in fuse boxes and small control panels. Both models have adjustable set points and LED indication to show there is power to the unit and when the switch activates. Set points can be adjusted using the potentiometer next to the LED’s. Due to the size of the switch, it is only offered in solid core and no core versions. The no core version has terminal blocks which can accept currents up to 1 A directly into the unit.

Features: 

  • Integral mounting flange for quick installation
  • Compact size fits in any space


Applications:

  • BAS
  • HVAC.

 

Other Details:

ModelCaseSet PointMinimum Set Point (A)LED
MCS-111050Solid coreAdjustable0.5Red/geen
MCS-111001No core (terminal connection)Adjustable0.01Red/geen



Additional Information:

  • Item Code: Series-MCS


Series SCS Current Switch

Rs 3,250 / Piece

BrandDwyer Usa
Temperature Range5 to 140 Degree F (-15 to 60 Degree C).
ConditionNew
ModelSeries-SCS
ApplicationBAS
Frequency50/60 Hz.
Place Of OriginDELHI
OutputIsolated, 1 A 30 VAC/DC max, NO.
External RelaySPST N.O., 10A at 260 VAC (5A at 30 VDC).
PowerNone, self-powered.
Isolation Voltage600 VAC RMS.
Enclosure RatingUL, 94 V-O flammability rated, ABS plastic housing.

Series SCS Current Switch

The Series SCS Low Cost Current Switches are ideal for monitoring whether fans, pumps, or motors are operating. The current flowing through the core of the device powers the circuit without an external power supply. All models have a built in solid state output and are easy to install. Optional LED’s and 10 Amp relay modules are available. The Series SCS is available in both Split and Solid Core configurations.

Features:

  • Integral mounting flange for quick installation
  • Solid core or split core configurations


Applications:

  • BAS
  • HVAC

Other Details:

ModelCaseAmperage RangeSet PointSwitch ModeSnap-on Relay
SCS-120025Solid.25 to 200 A0.25 fixedUnderNo
SCS-111100Solid1 to 135 AAdjustableOver/underNo
SCS-111100-RSolid1 to 135 AAdjustableOver/underYes
SCS-220015Split.15 to 200 A0.15 fixedUnderNo
SCS-220150Split1.5 to 200 A1.5 fixedUnderNo
SCS-211125Split1.25 to 135 AAdjustableOver/underNo
SCS-220150-RSplit1.5 to 200 A1.5 fixedUnderYes
SCS-211125-RSplit1.25 to 135 AAdjustableOver/underYes


Additional Information:

  • Item Code: Series-SCS


Vibration Transmitter

Rs 24,500 / Piece

BrandDWYER USA
Temperature Range-22 to 221 Degree F (-30 to 105 Degree C).
ApplicationIndustrial
Weight0.28 lb (0.125 kg)
Model NoModel-VBT-1
ConditionNew
Usage/ApplicationMotors
Enclosure RatingNEMA 6 (IP68).
Housing Material316 SS.
Electrical Rating9.6 to 32 VDC.
Frequency Range10 to 1000 Hz.
Output Signal4 to 20 mA.

Vibration Transmitter

The Model VBT-1 Vibration Transmitter continuously detects the vibration in a system and monitors for unusual operating conditions and potential failure. The vibration is converted into an analog signal at the current output. The VBT requires no setup, and there is no software required for configuration. The 2-wire loop power operation, combined with standard M12 micro cable connector and interchangeable mounting studs (1/4″-28 UNF/M8 (2) or the 1/4″-28 UNF), makes for a fast and reliable installation.

Features:

  • Easy set-up and operating concept
  • Stainless steel housing
  • No software required


Specification:

  • Accuracy : < ±3%.
  • Connections : M12 connector.
  • Mounting Orientation : Any position.
  • Nonlinearity : < ±0.25% of span.
  • Repeatability : < 0.5%.


Applications:

  • Motors
  • Pumps
  • Fans
  • Engines
  • Compressors
  • Gear boxes



Additional Information:

  • Item Code: Model-VBT-1
 


Series CCS Current Switch

Rs 1,850 / Piece

Model NumberSeries-CCS
Temperature-22 to 158 Degree F (-30 to 7 Degree C).
Humidity0 to 95% (non-condensing).
Application/UsageBAS
ConditionNew
BrandDWYER USA
ConnectionNew
Frequency40 to 400 Hz.
Usage/ApplicationHVAC
Amperage Range0 to 200 A AC.
OutputNormally open, NPN.
Isolation Voltage2000 V.
Enclosure RatingUL, 94 V-O flammability rated, ABS plastic housing.

Series CCS Current Switch

The SERIES CCS Current Switches are ideal for monitoring the operating status of fans, pumps, and motors. These self-powered switches can be hung or tied directly to cables or wires. For use on existing installations, split core models can be installed without disconnecting cables. LED indicators provide a visual confirmation that the current is flowing through the core. Both fixed and adjustable set points are available. The adjustable models utilize a potentiometer to easily adjust the set point.

Features:

  • Integral mounting flange for quick installation
  • Solid core or split core configurations
  • LED Indicator
  • Maximum Switch Rating : For fixed set point models: 0.3 A @ 135 VAC/DC; For adjustable set point models: 1 A @ 240 VAC.


Applications:

  • BAS
  • HVAC

 

Other Details:

ModelCaseSet PointMinimum Set Point (A)LEDDry Contact Output
CCS-121050Solid coreFixed0.50 (±0.2)RedYes
CCS-111100Solid coreAdjustable1.00 (±0.2)Red/greenNo
CCS-221100Split coreFixed1.00 (±0.2)RedYes
CCS-211150Split coreAdjustable1.50 (±0.2)Red/greenNo
CCS-131100Solid coreAdjustable1.00 (±0.2)Red/greenYes
CCS-231150Split coreAdjustable1.50 (±0.2)Red/greenYes


Additional Information:

  • Item Code: Series-CCS


Bar Graph Meter

Rs 8,500 / Piece

ModelSeries-BGM
Accuracy+/-0.05% FS.
Conditionnew
Storage Temperature-67 to 176 Degree F (-55 to 80 Degree C).
UsageLaboratory
Weight40 oz (1.13 kg)
Operating Temperature13 to 176 Degree F (-25 to 80 Degree C)
BrandDWYER USA
Enclosure RatingNEMA 1 or NEMA 4Xt model dependent IP65 front.
Decimal Point3 positions, user selectable.
Outputs2 SPST relay outputs (optional).
Time Delay0.5 S
Input Range0 to +/-10 VDC or 4 to 20 mA.

Bar Graph Meter

The Series BGM Digital Bar Graph Meter is extremely durable and can replace a wide range of analog meters. The 4-digit display will significantly reduce the potential for human error in reading by eliminating errors commonly produced by the viewing angle when reading analog meters. This series has a key pad that allows for easy access of features without complex menu structures. With the combined ability to create a wide range of custom faceplate and the optional NEMA 4X bezel, the Series BGM can be used in a variety of applications. The LED bar graph adds a visual indicator of the measured value so that it can be visually analyzed, preventing accidents or system failures from happening.

Features: 

  • Bar graph visual indicator
  • High resolution for better precision
  • Many configurable options to design a meter for any need


Specification:

  • Power Requirements : 120 VAC 50/60 Hz, 5 to 12 VDC, or 10 to 30 VDC model dependent.
  • Power Consumption : 120 VAC: 2.4 W @ 20 mA max; 5 to 12 VDC: 1.2 W @ 100 mA max; 10 to 30 VDC: 1.5 W @ 50 mA max.
  • Display : LED Display: 4 red colored digits, 0.3″ height; LED Graph: 31 element bar, 0.2″ W x 3.1″ L (5.08 mm W x 78.74 mm L).
  • Electrical Connections : Removable screw terminal blocks.
  • Switch Rating : 1 A @ 200 V.
  • Enclosure Material : Bezel: Black epoxy enameled steel; Window: Acrylic; Case and Mounting Bracket: 304 SS.


Applications:

  • Visual location and indication of flow, level or air velocity



Additional Information:

  • Item Code: Series-BGM
 


Digital Timer / Tachometer / Counter

Rs 750 / Piece

Operating Temp.32 to 122 Degree F (0 to 50 Degree C).
Humidity35 to 85% RH (non-condensing).
ApplicationIndustrial
Weight4 oz (114 g).
Model NumberSeries-LCT216
Display TypeDigital
BrandDWYER USA
ConditionNew
Reset Time0.001 S. minimum.
Power Requirements100 to 240 VAC 50 / 60 Hz.
Power ConsumptionLess than 10 VA.
Internal Power Supply12 VDC +/-10%, 100 mA.

Digital Timer / Tachometer / Counter

The Series LCT216 combines a versatile timer, counter, and tachometer in one device. The bright, easy-to-read display shows both the desired set point and the current process value as well as the operating mode that the control is functioning in. The fourteen pre-programmed timer functions are easy to set up and cover most applications. The counting functions include one stage or two stage counting along with batch, total, or dual counting modes. The Series LCT216 can also be used as a tachometer to measure rotational speeds. For quick set up, many of the programming parameters can be set with external dip switches located on the side of the unit.

Features: 

  • Fourteen pre-programmed timer functions
  • One stage, two stage, batch, total, and dual counting modes


Specification:

  • Control Output Ratings : (Out 1) Relay: SPST 5A at 250 VAC, Transistor: NPN Open collector 100 mA / 30 VDC residual voltage = 1.5 VDC max; (Out 2) Relay: SPST 5A at 250 VAC, Transistor: NPN Open collector 100 mA / 30 VDC residual voltage = 1.5 VDC max.
  • Inputs : Dry contact, PNP, or NPN.
  • Timing Functions : 14 pre-programmed timing functions.
  • Display : Two-line 6 digit negative transmissive LCD display.


Applications:

  • Industrial ovens
  • Batch counting in conveyor systems
  • Silk screening equipment




Additional Information:

  • Item Code: Series-LCT216
 


Electronic Fan Speed Control

Rs 4,500 / Piece

ConditionNew
Weight1 lb 11 oz (.77 kg).
Model NumberModel-FC-1000
ConnectionNew
Temperature Range-40 to 131 Degree F (-40 to 55 Degree C).
BrandDWYER USA
Line Voltage Range120-277 VAC, 60 Hz.
Input Signal Voltage0-10 VDC.
Low Voltage Input24 VAC, Class 2
Input Signal Impedance10K ohms.
Locked Rotor Amp Rating24.0.
Enclosure RatingNEMA 1.
Electronic Fan Speed Control

The Model FC-1000 Electronic Fan Speed Control provides precise speed modulation of small AC motors. Popular 0-10 VDC input works with most process controllers, eliminating the need for more expensive dampers, damper actuators and linkages while improving overall energy efficiency of the system. This inexpensive unit enables variable control ventilation fans, condenser fans and interfacing with VAV box controllers.

 

Features:
  • Compact design allows for use in most areas
  • Improves energy efficiency in systems

Specification:

  • Full Load Amp Rating : 9.8 @ 120 VAC, 9.3 @ 208 VAC, 8.0 @ 240 VAC, 6.9 @ 277 VAC.
  • Electrical Connections : Line voltage: 10-32 screw terminals; Signal and low voltage input: 1/4″ quick connects.
  • Transient Protection : 320V surge suppression. Exceeds IEEE C62.41 standards.
  • Housing Materials : Cold rolled steel.
  • Mounting : Vertical only; four holes provided for 10 screws.

 

Applications:

  • Monitoring fans and motors


Additional Information:

  • Item Code: Model-FC-1000

 

 
 


Ice Cube Relays

Rs 12 / Piece

Model NoSeries-784-4PDT
Model Number784-4PDT
Weight2.8 oz (80 g).
BrandDWYER USA
ConditionNew
ApplicationHVAC motor controls
Operating and Load Voltage Range24 to 120 VAC, 24 VDC
Switching Operation4PDT
Electrical Rating15 A 120 VAC 50/60Hz; 12 A 277 VAC 50/60 Hz or 28 VDC.
Storage Temperature-40 to 185 Degree F (-40 to 85 Degree C)
Operation Temperature-40 to 131 Degree F (-40 to 55 Degree C).
Power Consumption1.5 VA; 1.5 W.
Cycle Life200000 cycles (electrical); 10000000 cycles (mechanical).
HousingPlastic polycarbonate.

Ice Cube Relays

The Series 784 Electromechanical Ice Cube Relay is a full-featured 4PDT relay that can be used to handle loads up to 15 amps for AC or DC circuits. Utilizing the same trigger, this relay can be used in underground parking garage applications to signal audible and visual alarms for high levels of carbon monoxide, while opening the dampers and starting the exhaust fans. It features a flag status indicator and a LED status lamp to let the user know when the relay is activated. In order to differentiate between AC and DC actuated models, the push-to-test button is color-coded. For testing the operation, a removable lockdown lever holds the test button in place. The clear plastic housing gives a view of the contacts and there is a removable I.D. tag for labeling the circuit.

Features:

  • Clear plastic housing to easily view the contacts
  • Flag and LED status indicators for visual confirmation of relay state
  • Socket mounted for quick installation/replacement


Applications:

  • Refrigeration compressor systems
  • HVAC motor controls
  • Water/wastewater pump control



Additional Information:

  • Item Code: Series-784-4PDT
 


Low Cost Digital Timer

Rs 6,700 / Piece

ModelSeries-LCT316
BrandDWYER USA
Weight5.6 oz (158.8 g).
Usage/ApplicationCommercial cooking equipment
Display TypeDigital
ApplicationsCommercial dish washers and refrigeration equipment
Item CodeSeries-LCT316
Operating Temperature32 to 158 Degree F (0 to 70 Degree C).
Control Output RatingsRelay, SPST, 16A at 250 VAC resistive.
Status LightLED shows time and operation.
InputsDigital input for start and reset.
Supply Voltage115 VAC, 230 VAC, 12 VAC/DC, 24 VAC/DC depending on model
Power Consumption4VA

Low Cost Digital Timer

The Series LCT316 Low Cost Digital Timer provides accurate countdown timing for a variety of applications. The timer can be triggered remotely using the digital input terminals or locally via the set button. Time intervals can be set up to 999 minutes or seconds. The Series LCT316 has an internal buzzer to alert when the time interval has expired.

Features:

  • 1 second to 999 minute field set time interval
  • Audible alarm for status indication


Applications:

  • Commercial cooking equipment
  • Commercial dish washers and refrigeration equipment

 

Other Details:

ModelSupply Power
LCT316-100115 VAC
LCT316-200230 VAC
LCT316-30012 VAC/DC
LCT316-40024 VAC/DC

 



Additional Information:

  • Item Code: Series-LCT316


Particulate Monitor

Rs 50,000 / Piece

BrandDWYER USA
ConditionNew
Model NoSeries-DPM
Usage/ApplicationBaghouses
Weight4.5 lbs (2.0 kg)
InputsFrom PMS Sensor.
Power Requirement115 VAC 50/60 Hz, 230 VAC 50/60 Hz, or 24 VDC.
Power Consumption6 Watts Max.
DisplayLCD
Temperature-13 to 160 Degree F (-25 to 70 Degree C).

Particulate Monitor

The DPM Particulate Monitor and PMS Particulate Sensor combine to provide a basic baghouse and cartridge filter leak detector designed for general maintenance planning and process protection. It is easy to use and reliable. Leakage is gaged in real-time, on-the-spot, without prior baseline data and without signal tuning. Simply apply power and the general condition of the filter is quickly determined. An alarm point is set by simply moving an indicator up and down the gage with the convenient, lockable key pad. For more precise alarm setup the large display provides both a logarithmic analog bar graph and an absolute digital readout. The log scale enables the user to observe both the baseline bleed through and the high peaks that are caused by filter cleaning cycles and developing leaks. Observation of both baseline and peaks is essential to setting proper alarms. The digital readout in absolute units ensures correct interpretation of the readings and provides accurate historical comparisons.

 

The DPM Particulate Monitor is housed in a rugged cast aluminum enclosure. An LCD displays particulate levels in bar-graph and digital forms. A lockable membrane keypad is provided for setup and adjustment.

 

Features:

  • Rugged cast aluminum housing with lockable membrane keypad
  • Programmable alarm points
  • Large LCD to display readouts digitally


Specification:

  • Output Ratings : Alarm Relays: 2 Form A (SPST) rated 5A @ 240V res. (must provide an 8A [maximum] fuse in series with relay load); Analog: 4 to 20 mA (Option RC).
  • Accuracy : Standard: ±5% of range; Optional: ±1% of range.
  • Display Resolution : Standard: 5 pA; Optional: 0.5 pA.
  • Memory Backup : For set point storage only.
  • Enclosure : Cast aluminum, weatherproof, NEMA 4X.
  • Loop Power Supply (Isolated) : 17 VDC loop supply provided by DPM control unit for PMS sensor.


Applications:

  • Baghouses
  • Cartridge Filters
  • Bin Vents

Request
Callback


Additional Information:

  • Item Code: Series-DPM
 


Particulate Sensor

Rs 20,700 / Piece

Model NumberSeries-PMS
Ambient Temperature-40 to 392 Degree F (-40 to 200 Degree C)
ConnectionNew
ConditionNew
BrandDWYER USA
Application/UsageCartridge Filters
Usage/ApplicationBaghouses
Wetted Materials304SS and PTFE.
Electrical ConnectionLow noise coaxial.

Particulate Sensor

The PMS Particulate Sensor employs a field-proven combination of passive-induction and protected-probe technologies. As particles flow near and around the probe, minute currents are dynamically induced into the probe by flowing particulate. A DSP processes the signal into an absolute output that is reasonably linear to mass. Protective layers over the probe work in combination with induction-sensing to ensure reliable operation with all types of particulate including moist powders and highly conductive dusts. Maintenance is minimal and there is no need for an air purge. For durability, the sensors are passive and free of electronics. The PMS Particulate Sensor is designed to be used with the DPM Particle Monitor in order to be intrinsically safe.

Features:

  • Durable housing that is free of electronics
  • Minimal maintenance needed


Specification:

  • Service : Air and compatible gases, any type particulate.
  • Pressure Limits : Standard: Full vacuum to 10 psi (0.69 bar); Optional: 100 psi (6.89 bar).
  • Output Signal : pA.
  • Enclosure : Standard: Painted cast aluminum, weatherproof, NEMA 4X; Optional: Intrinsically Safe, CSA.
  • Weight : Varies depending on length of probe and type of mount.


Applications:

  • Baghouses
  • Cartridge Filters
  • Bin Vents



Additional Information:

  • Item Code: Series-PMS
 


Particulate Transmitter

Rs 22,000 / Piece

ApplicationFilter leak or wear detection
Usage/ApplicationBin vent monitoring
Accuracy+/-5% of reading.
Model NumberSeries-PMT2
Output Signal4 to 20 mA.
EnclosurePowder coated aluminum.
BrandDWYER USA
ConditionNew
Application/UsageBroken bag detection in dust collectors
ApplicationsEmissions monitoring
Wetted Materials316L SS, silicone, and PTFE.
Particulate Size0.3 microns and higher.
Detection Range5 to 5000 pA (6 selectable range options).
Pressure Limit30 psi (2 bar).
Power Requirements12 to 28 VDC.

Particulate Transmitter

The SERIES PMT2 Particulate Transmitter is designed to measure particulate emission levels from dust collector discharge. Using DC coupled electrostatic induction sensing technology, the transmitter monitors a pA current that is generated as particulate passes near the probe; a 4 to 20 mA signal will vary based on the particulate level. The PMT2 offers 6 sensitivity ranges allowing the user to choose the range that will best fit the application. The range and test selector switch can also be set to output a 4 mA or 20 mA signal to assist with set up or trouble shooting. Averaging time setting can be used to dampen the signal if desired.

Features:

  • Simple 2-wire installation for PLC and control panels
  • Non-stick PTFE coated probe to prevent false readings from moist and conductive dusts, condensate, and dust buildup
  • Remote zero calibration helps to decrease maintenance time


Specification:

  • Temperature Limits:Ambient: -40 to 145°F (-40 to 63°C); Process: -40 to 248°F (-40 to 120°C).
  • Electrical Connection : Two 1/2″ female NPT conduit openings.
  • Terminal Block : Removable (16 to 20 AWG wire).
  • Enclosure Rating : Type 4 (IP66).
  • Mounting Orientation : Any.
  • Averaging Time : 1 to 360 s (10 selectable options).
  • Weight: Varies with length of probe and type of mount.


Applications:

  • Emissions monitoring
  • Broken bag detection in dust collectors
  • Filter leak or wear detection
  • Bin vent monitoring




Additional Information:

  • Item Code: Series-PMT2
 


Process Indicator

Rs 5,500 / Piece

Usage/ApplicationDisplay process values from various transmitters
ConditionNew
ModelSeries-LCI132
Display TypeDigital
Humidity Range95% 40 Degree C.
BrandDWYER USA
Temperature Coefficient100 ppm/ Degree C.
Warm Up5 minutes
Operating Temperature-10 to 60 Degree C
Storage Temperature-25 to +85 Degree C
Panel SealingNEMA 4X (IP66).

Process Indicator

THE SERIES LCI132 PROCESS INDICATORS offer flexibility and value in a low cost, compact 1/32 DIN package. The shallow depth of these full size panel meters allows installation in panels only 2.76″ (70 mm) deep with room to spare.

Features:

  • Fits in 1/32 DIN panel cutouts
  • IP65 (NEMA 4X) front housing
  • Fully programmable
  • Various voltage and current inputs fits most processes


Specification:
Model – LCI132-0X

  • Range : Input Volts (DC): ±200 V, ±20 V, ±10 V; Input Amperes: ±100 mV, ±20 mA;
  • Resolution : Input Volts (DC): 0.1 V, 0.01 V, 1 mV; Input Amperes: 0.1 mV, 0.01 mA; Input Impedance: Volts: 1 M Ω, mV: 100 M Ω, mA: 12.1 Ω.


Model – LCI132-1X

  • Range AC : Input Volts: 600.0, 100.0; Input Amperes: 5.000, 1.000;
  • Range DC : Input Volts: -199.9, ±600.0, ±100.0; Input Amperes: -1.999, +5.000, ±1.000;
  • Resolution : Input Volts: 0.1 V; Input Amperes: 1 mA Input Impedance: Volts: 3 M Ω (106), Amps: 12 m Ω (10-3).
  • Accuracy at 23ºC ±5ºC : 100/600 VDC 1/5 A DC; 600V/5A AC: ±(0.2% reading + 3 digits). 100 V / 1A AC: ±(0.4% reading + 4 digits).


Power Supply and Fuses (DIN 41661) (Not supplied):

  • LCI132-X0 : 85–265 VAC 50/60 Hz and 100-300 VDC: Fuse: 0.1A/ 250V.
  • LCI132-X1 : 21-53 VAC 50/60Hz and 10.5-70 VDC: Fuse 0.5A/ 250V.


Display:

  • LCI132-X0 : 85–265 VAC 50/60 Hz and 100-300 VDC: Fuse: 0.1A/ 250V.
  • LCI132-X1 : 21-53 VAC 50/60Hz and 10.5-70 VDC: Fuse 0.5A/ 250V.


Applications:

  • Display process values from various transmitters

 

Other Details:

ModelInputSupply Voltage
LCI132-00±100 VDC; ±20 VDC; ±10 VDC; ±200 VDC; ±20 mA DC120/240 VAC
LCI132-01±100 VDC; ±20 VDC; ±10 VDC; ±200 VDC; ±20 mA DC24/48 VAC
LCI132-10±100 VAC; 600 VAC; 5 A (DC) 1A (AC); -199.9 to +600 VDC; ±100 VDC -1.999 to 5 A (DC) ±1 A (DC);120/240 VAC
LCI132-11±100 VAC; 600 VAC; 5 A (DC) 1 A (AC); -199.9 to +600 VDC; ±100 VDC -1.999 to 5 A (DC) ±1 A (DC);24/48 VAC


Additional Information:

  • Item Code: Series-LCI132

 

Process and Temperature Alarm Switch Module

 

Rs 6,500 / Piece

Operating Temperature32 to 131 Degree F (0 to 55 Degree C).
Model No.Series-SC1
Storage Temperature-40 to 176 Degree F (-40 to 80 Degree C).
BrandDWYER USA
Usage/ApplicationIndustrial processing equipment
ApplicationStand alone CO monitoring in parking garage
Isolation1500 V rms between outputs, input, and power.
Set PointsAdjustable 0 to 100% of span.
DeadbandAdjustable 0.25% to 100% of span.
Dimension2.95″ H x 0.89″ W x 3.89″ D (75 x 22.5 x 98.5 mm).

Process and Temperature Alarm Switch Module

The Series SC1 Thermocouple Limit/Alarm Switch Modules are on-off or limit switches with selectable process signal. Input type, scale range, output action, and output type are all selectable by the user in the field. All selections are made through easily accessible switches without the need to open the product. Each unit has two form C (SPDT) relays which can operate independently, or be logically connected to operate as a DPDT output. A two color LED indicator indicates the status of each output relay.

These units mount easily on a standard 35 mm DIN rail. Low Voltage (SCLXXXX) units are also available.

 

Features:

  • Accepts current, voltage, thermocouple, or RTD inputs
  • Mounts on standard 35 mm DIN rail
  • Two color LED indicator to indicate the status of each output relay
  • Programmable input type, scale range, output action, and output type

 

Specification:

  • Power Supply : SC models: 85 to 265 VDC/VAC, 50 to 400 Hz; SCL models: 12 to 24 VDC/VAC, 50 to 400 Hz.
  • Drift  : ±0.02%/°C typical ±0.05%/°C maximum.
  • Excitation Current : (SC1490) Cu10Ω = 5 mA; Plt 100Ω, Ni 100Ω, Ni 120Ω = 500µA; Plt 500Ω, NiFe 1000Ω = 100 µA; Plt 1000Ω = 50 µA.
  • Lead Compensation Error : (SC1490) ˜ 0.02%/Ω.
  • Open Lead Protection : (SC1490) upscale only.
  • Input Impedance : SC1090: Voltage input = 1 MΩ, current input = 10Ω; SC1290: 3 MΩ.
  • Sensor Burnout Protection : Selectable.
  • Relay Output : Form C, SPDT, one per set point, 5A @ 250 VAC, resistive.
  • Latch Circuit Reset : Automatic at power up. Manual with reset switch on front of module.
  • Indicators : One dual color LED per set point. Red = relay on, green = relay off.
  • Wiring Terminals : Screw driven compression type.


Applications:

  • Stand alone CO monitoring in parking garage
  • Industrial processing equipment

Other Details:

ModelDescriptionPower Supply
SC10904 to 20 mA, 10 to 50 mA, 0 to 20 mA, 0 to 10 V, -10 to 10 mV85 to 265 VDC/VAC
SC1290Thermocouple type J, K, R, S, T, E85 to 265 VDC/VAC
SC1490RTD Pt1000 Ni100, Ni120, Cu10, Ni-Fe1000, Ni-Fe200085 to 265 VDC/VAC
SCL10904 to 20 mA, 10 to 50 mA, 0 to 20 mA, 0 to 10 V, -10 to 10 mV12 to 24 VDC/VAC
SCL1290Thermocouple type J, K, R, S, T, E12 to 24 VDC/VAC
SCL1490RTD Pt1000 Ni100, Ni120, Cu10, Ni-Fe1000, N-Fe200012 to 24 VDC/VAC


Additional Information:

  • Item Code: Series-SC1


Zener Barrier

Rs 1,700 / Piece

Weight4.9 oz (140 g).
Power20 to 35 VDC w.r.t. earth.
Model NumberSeries-MTL7706-7787
BrandDWYER USA
ConnectionNew
ConditionNew
Storage Temperature-40 to 176 Degree F (-40 to 80 Degree C).
Usage/ApplicationElectrically isolates pressure and level transmitters from unregulated circuits for intrinsically sa
Safe Area Output4 to 20 mA.
LED IndicatorGreen Power Indication.
Operating Temperature-4 to 140 Degree F (-20 to 60 Degree C)
Humidity5 to 95% RH.


Zener Barrier

The MTL7706/7787 is an intrinsically safe (IS) shunt-diode barrier that can be used to communicate with and provide isolations for certain Dwyer® transmitters approved for use in hazardous areas. These barriers limit the amount of energy allowed to pass into the hazardous area, which inhibit ignition in flammable atmospheres.

Features: 

  • Approved for use in hazardous areas


Specification:

  • Transmitter Voltage : 16.2 V @ 20 mA with 250Ω load (negative w.r.t. earth); 11.0 V @ 20 mA with 500Ω load (negative w.r.t. earth).
  • Accuracy : ±2 µA under all conditions.
  • Terminals : Accommodate up to 2.5 mm² stranded or single-core.
  • Safety Description : 28 µV, 300Ω, 93 mA.


Applications:

  • Electrically isolates pressure and level transmitters from unregulated circuits for intrinsically safe application

Request
Callback


Additional Information:

  • Item Code: Series-MTL7706-7787