SERIES DM DIGIMAG® DIFFERENTIAL PRESSURE TRANSMITTER

Dwyer DM-001 DigiMag Differential Pressure Transmitter, 0.1 inWC-

SERIES DM DIGIMAG® DIFFERENTIAL PRESSURE TRANSMITTER

Same Size as Standard Magnehelic® Differential Pressure Gage

The Series DM DigiMag® Differential Pressure Transmitter senses the pressure of air and compatible gases and sends a standard 4-20 mA output signal. The DM housing is specifically designed to mount in the same diameter cutout as a standard Magnehelic® gage. A wide range of models are available factory calibrated to specific ranges. The polycarbonate molded housing features integral pressure connections, which reduces installation time. Digital push-button zero and span simplify calibration over typical turn-potentiometers. A single push-button allows field selection of 4 to 6 engineering units, depending on the range.

PRODUCT APPLICATIONS

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
  • Room pressurization monitoring

MODELS & ORDERING

Model Description
DM-001 Differential digital pressure transmitter, range 0-0.1″ w.c.
DM-002 Differential digital pressure transmitter, range 0-0.25″ w.c.
DM-003 Differential digital pressure transmitter, range 0-0.5″ w.c.
DM-004 Differential digital pressure transmitter, range 0-1.0″ w.c.
DM-005 Differential digital pressure transmitter, range 0-2.0″ w.c.
DM-007 Differential digital pressure transmitter, range 0-3.0″ w.c.
DM-008 Differential digital pressure transmitter, range 0-5.0″ w.c.
DM-202 Differential digital pressure transmitter, range 0.25-0-0.25″ w.c.
DM-203 Differential digital pressure transmitter, range 0.5-0-0.5″ w.c.

SPECIFICATIONS

  • Service:Air and non-combustible, compatible gases.
  • Wetted Materials:Consult factory.
  • Housing Material:Polycarbonate.
  • Accuracy:±1% FSO for all ranges except 0.25 in w.c. @ ±2% FSO, and ranges at or below ±0.1 in w.c. @ ±4% FSO.
  • Stability:< ±1%/year FSO.
  • Pressure Limits:Ranges > 1 in w.c.: 6 psi max operation, 6 psi burst; Ranges = 1 in w.c.: 3.6 psi max operation, 6 psi burst.
  • Temperature Limits:-4 to 158°F (-20 to 70°C).
  • Thermal Effect:0.036% FS/°C (0.02% FS/°F).
  • Power Requirements:10-35 VDC (2-wire).
  • Output Signal:4-20 mA (2-wire).
  • Zero and Span Adjustments:Push-button.
  • Loop Resistance:0 to 1250 Ω max.
  • Current Consumption:21 mA max.
  • Electrical Connections:Screw-type terminals.
  • Process Connections:Male ports on side for 1/8″, 3/16″, 1/4″, 5 mm, 6 mm ID flexible tubing.
  • Enclosure Rating:NEMA 4X (IP66).
  • Mounting Orientation:Not sensitive to position.
  • Size:5″ OD (127 mm) x 1.9″ (48 mm) deep.
  • Weight:7.04 oz (200 g).
  • Agency Approvals:CE.

FEATURES

  • Reduced installation time through zero and span controls that provides quick and easy calibration
  • Fast and easy setup and calibration with push-button zero and span controls
  • Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
  • Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic® gage, as both use the same diameter cutout
































Dwyer DM-001 DigiMag Differential Pressure Transmitter, 0.1 inWC

Dwyer DM-001 DigiMag Differential Pressure Transmitter, 0.1 inWC

Model: DM-001

Senses the pressure of air and compatible gases, this differential pressure transmitter features a pressure range of 0.1 inWC and has a 4 to 20 mA output. Fast and easy to set up, this transmitter is suitable for fan control, static pressures in ducts or buildings, room pressurization monitoring, and differential pressure across filters.

Dwyer DM-001 Offers

Specifically designed to mount in a standard Magnehelic® gauge cutout, this pressure transmitter features a polycarbonate molded housing with integral pressure connections, reducing installation time. In addition, the digital push-button zero and span simplify calibration over typical turn-potentiometers, and a single push-button allows field selection of multiple engineering units.

Features

  • Reduced installation time through zero and span controls that provides quick and easy calibration
  • Fast and easy setup and calibration with push-button zero and span controls
  • Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
  • Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic® gauge, as both use the same diameter cutout

Applications

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
  • Room pressurization monitoring

Dwyer DM-001 Specifications

Service Air and non-combustible, compatible gases
Pressure Range 0.1 inWC
Accuracy ±4% FSO
Stability <±1%/year FSO
Limits Pressure: 3.6 psi maximum operation, 6 psi burst
Temperature: -4 to 158°F (-20 to 70°C)
Thermal Effect 0.02% FS/°F (0.036% FS/°C)
Output Signal 4 to 20 mA (2-wire)
Zero and Span Adjustments Push-button
Loop Resistance 0 to 1250 Ω maximum
Current Consumption 21 mA maximum
Connections Electrical: Screw-type terminals
Process: Male ports on side for ⅛”, 316“, ¼”, 0.2″ (5 mm), 0.23″ (6 mm) ID flexible tubing
Power Requirements 10 to 35 V DC (2-wire)
Enclosure Rating NEMA 4X (IP66)
Mounting Orientation Not sensitive to position
Agency Approvals CE
Housing Material Polycarbonate
Dimensions Ø5 x 1.9″ (Ø127 x 48.2 mm)
Weight 7.04 oz (200 g)

What’s included with the Dwyer DM-001

  • Dwyer DM-001 DigiMag Differential Pressure Transmitter, 0.1 inWC

Dwyer DM-002 DigiMag Differential Pressure Transmitter, 0.25 inWC

Dwyer DM-002 DigiMag Differential Pressure Transmitter, 0.25 inWC

  • Model: DM-002

Senses the pressure of air and compatible gases, this differential pressure transmitter features a pressure range of 0.25 inWC and has a 4 to 20 mA output. Fast and easy to set up, this transmitter is suitable for fan control, static pressures in ducts or buildings, room pressurization monitoring, and differential pressure across filters.

Dwyer DM-002 Offers

Specifically designed to mount in a standard Magnehelic® gauge cutout, this pressure transmitter features a polycarbonate molded housing with integral pressure connections, reducing installation time. In addition, the digital push-button zero and span simplify calibration over typical turn-potentiometers, and a single push-button allows field selection of multiple engineering units.

Features

  • Reduced installation time through zero and span controls that provides quick and easy calibration
  • Fast and easy setup and calibration with push-button zero and span controls
  • Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
  • Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic® gauge, as both use the same diameter cutout

Applications

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
  • Room pressurization monitoring

Dwyer DM-002 Specifications

Service Air and non-combustible, compatible gases
Pressure Range 0.25 inWC
Accuracy ±2% FSO
Stability <±1%/year FSO
Limits Pressure: 3.6 psi maximum operation, 6 psi burst
Temperature: -4 to 158°F (-20 to 70°C)
Thermal Effect 0.02% FS/°F (0.036% FS/°C)
Output Signal 4 to 20 mA (2-wire)
Zero and Span Adjustments Push-button
Loop Resistance 0 to 1250 Ω maximum
Current Consumption 21 mA maximum
Connections Electrical: Screw-type terminals
Process: Male ports on side for ⅛”, 316“, ¼”, 0.2″ (5 mm), 0.23″ (6 mm) ID flexible tubing
Power Requirements 10 to 35 V DC (2-wire)
Enclosure Rating NEMA 4X (IP66)
Mounting Orientation Not sensitive to position
Agency Approvals CE
Housing Material Polycarbonate
Dimensions Ø5 x 1.9″ (Ø127 x 48.2 mm)
Weight 7.04 oz (200 g)

What’s included with the Dwyer DM-002

  • Dwyer DM-002 DigiMag Differential Pressure Transmitter, 0.25 inWC

Dwyer DM-003 DigiMag Differential Pressure Transmitter, 0.5 inWC

Dwyer DM-003 DigiMag Differential Pressure Transmitter, 0.5 inWC

  • Model: DM-003

Senses the pressure of air and compatible gases, this differential pressure transmitter features a pressure range of 0.5 inWC and has a 4 to 20 mA output. Fast and easy to set up, this transmitter is suitable for fan control, static pressures in ducts or buildings, room pressurization monitoring, and differential pressure across filters.

Dwyer DM-003 Offers

Specifically designed to mount in a standard Magnehelic® gauge cutout, this pressure transmitter features a polycarbonate molded housing with integral pressure connections, reducing installation time. In addition, the digital push-button zero and span simplify calibration over typical turn-potentiometers, and a single push-button allows field selection of multiple engineering units.

Features

  • Reduced installation time through zero and span controls that provides quick and easy calibration
  • Fast and easy setup and calibration with push-button zero and span controls
  • Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
  • Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic® gauge, as both use the same diameter cutout

Applications

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
  • Room pressurization monitoring

Dwyer DM-003 Specifications

Service Air and non-combustible, compatible gases
Pressure Range 0.5 inWC
Accuracy ±1% FSO
Stability <±1%/year FSO
Limits Pressure: 3.6 psi maximum operation, 6 psi burst
Temperature: -4 to 158°F (-20 to 70°C)
Thermal Effect 0.02% FS/°F (0.036% FS/°C)
Output Signal 4 to 20 mA (2-wire)
Zero and Span Adjustments Push-button
Loop Resistance 0 to 1250 Ω maximum
Current Consumption 21 mA maximum
Connections Electrical: Screw-type terminals
Process: Male ports on side for ⅛”, 316“, ¼”, 0.2″ (5 mm), 0.23″ (6 mm) ID flexible tubing
Power Requirements 10 to 35 V DC (2-wire)
Enclosure Rating NEMA 4X (IP66)
Mounting Orientation Not sensitive to position
Agency Approvals CE
Housing Material Polycarbonate
Dimensions Ø5 x 1.9″ (Ø127 x 48.2 mm)
Weight 7.04 oz (200 g)

What’s included with the Dwyer DM-003

  • Dwyer DM-003 DigiMag Differential Pressure Transmitter, 0.5 inWC

Dwyer DM-004 DigiMag Differential Pressure Transmitter, 1 inWC

Dwyer DM-004 DigiMag Differential Pressure Transmitter, 1 inWC

  • Model: DM-004

Senses the pressure of air and compatible gases, this differential pressure transmitter features a pressure range of 1 inWC and has a 4 to 20 mA output. Fast and easy to set up, this transmitter is suitable for fan control, static pressures in ducts or buildings, room pressurization monitoring, and differential pressure across filters.

Dwyer DM-004 Offers

Specifically designed to mount in a standard Magnehelic® gauge cutout, this pressure transmitter features a polycarbonate molded housing with integral pressure connections, reducing installation time. In addition, the digital push-button zero and span simplify calibration over typical turn-potentiometers, and a single push-button allows field selection of multiple engineering units.

Features

  • Reduced installation time through zero and span controls that provides quick and easy calibration
  • Fast and easy setup and calibration with push-button zero and span controls
  • Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
  • Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic® gauge, as both use the same diameter cutout

Applications

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
  • Room pressurization monitoring

Dwyer DM-004 Specifications

Service Air and non-combustible, compatible gases
Pressure Range 1 inWC
Accuracy ±1% FSO
Stability <±1%/year FSO
Limits Pressure: 3.6 psi maximum operation, 6 psi burst
Temperature: -4 to 158°F (-20 to 70°C)
Thermal Effect 0.02% FS/°F (0.036% FS/°C)
Output Signal 4 to 20 mA (2-wire)
Zero and Span Adjustments Push-button
Loop Resistance 0 to 1250 Ω maximum
Current Consumption 21 mA maximum
Connections Electrical: Screw-type terminals
Process: Male ports on side for ⅛”, 316“, ¼”, 0.2″ (5 mm), 0.23″ (6 mm) ID flexible tubing
Power Requirements 10 to 35 V DC (2-wire)
Enclosure Rating NEMA 4X (IP66)
Mounting Orientation Not sensitive to position
Agency Approvals CE
Housing Material Polycarbonate
Dimensions Ø5 x 1.9″ (Ø127 x 48.2 mm)
Weight 7.04 oz (200 g)

What’s included with the Dwyer DM-004

  • Dwyer DM-004 DigiMag Differential Pressure Transmitter, 1 inWC

Dwyer DM-005 DigiMag Differential Pressure Transmitter, 2 inWC

Dwyer DM-005 DigiMag Differential Pressure Transmitter, 2 inWC

  • Model: DM-005

Senses the pressure of air and compatible gases, this differential pressure transmitter features a pressure range of 2 inWC and has a 4 to 20 mA output. Fast and easy to set up, this transmitter is suitable for fan control, static pressures in ducts or buildings, room pressurization monitoring, and differential pressure across filters.

Dwyer DM-005 Offers

Specifically designed to mount in a standard Magnehelic® gauge cutout, this pressure transmitter features a polycarbonate molded housing with integral pressure connections, reducing installation time. In addition, the digital push-button zero and span simplify calibration over typical turn-potentiometers, and a single push-button allows field selection of multiple engineering units.

Features

  • Reduced installation time through zero and span controls that provides quick and easy calibration
  • Fast and easy setup and calibration with push-button zero and span controls
  • Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
  • Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic® gauge, as both use the same diameter cutout

Applications

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
  • Room pressurization monitoring

What’s included with the Dwyer DM-005

  • Dwyer DM-005 DigiMag Differential Pressure Transmitter, 2 inWC

Dwyer DM-007 DigiMag Differential Pressure Transmitter, 3 inWC

Dwyer DM-007 DigiMag Differential Pressure Transmitter, 3 inWC

  • Model: DM-007

Senses the pressure of air and compatible gases, this differential pressure transmitter features a pressure range of 3 inWC and has a 4 to 20 mA output. Fast and easy to set up, this transmitter is suitable for fan control, static pressures in ducts or buildings, room pressurization monitoring, and differential pressure across filters.

Dwyer DM-007 Offers

Specifically designed to mount in a standard Magnehelic® gauge cutout, this pressure transmitter features a polycarbonate molded housing with integral pressure connections, reducing installation time. In addition, the digital push-button zero and span simplify calibration over typical turn-potentiometers, and a single push-button allows field selection of multiple engineering units.

Features

  • Reduced installation time through zero and span controls that provides quick and easy calibration
  • Fast and easy setup and calibration with push-button zero and span controls
  • Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
  • Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic® gauge, as both use the same diameter cutout

Applications

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
  • Room pressurization monitoring

Dwyer DM-007 Specifications

Service Air and non-combustible, compatible gases
Pressure Range 3 inWC
Accuracy ±1% FSO
Stability <±1%/year FSO
Limits Pressure: 6 psi maximum operation, 6 psi burst
Temperature: -4 to 158°F (-20 to 70°C)
Thermal Effect 0.02% FS/°F (0.036% FS/°C)
Output Signal 4 to 20 mA (2-wire)
Zero and Span Adjustments Push-button
Loop Resistance 0 to 1250 Ω maximum
Current Consumption 21 mA maximum
Connections Electrical: Screw-type terminals
Process: Male ports on side for ⅛”, 316“, ¼”, 0.2″ (5 mm), 0.23″ (6 mm) ID flexible tubing
Power Requirements 10 to 35 V DC (2-wire)
Enclosure Rating NEMA 4X (IP66)
Mounting Orientation Not sensitive to position
Agency Approvals CE
Housing Material Polycarbonate
Dimensions Ø5 x 1.9″ (Ø127 x 48.2 mm)
Weight 7.04 oz (200 g)

What’s included with the Dwyer DM-007

  • Dwyer DM-007 DigiMag Differential Pressure Transmitter, 3 inWC

Dwyer DM-008 DigiMag Differential Pressure Transmitter, 5 inWC

Dwyer DM-008 DigiMag Differential Pressure Transmitter, 5 inWC

  • Model: DM-008

Senses the pressure of air and compatible gases, this differential pressure transmitter features a pressure range of 5 inWC and has a 4 to 20 mA output. Fast and easy to set up, this transmitter is suitable for fan control, static pressures in ducts or buildings, room pressurization monitoring, and differential pressure across filters.

Dwyer DM-008 Offers

Specifically designed to mount in a standard Magnehelic® gauge cutout, this pressure transmitter features a polycarbonate molded housing with integral pressure connections, reducing installation time. In addition, the digital push-button zero and span simplify calibration over typical turn-potentiometers, and a single push-button allows field selection of multiple engineering units.

Features

  • Reduced installation time through zero and span controls that provides quick and easy calibration
  • Fast and easy setup and calibration with push-button zero and span controls
  • Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
  • Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic® gauge, as both use the same diameter cutout

Applications

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
  • Room pressurization monitoring

Dwyer DM-008 Specifications

Service Air and non-combustible, compatible gases
Pressure Range 5 inWC
Accuracy ±1% FSO
Stability <±1%/year FSO
Limits Pressure: 6 psi maximum operation, 6 psi burst
Temperature: -4 to 158°F (-20 to 70°C)
Thermal Effect 0.02% FS/°F (0.036% FS/°C)
Output Signal 4 to 20 mA (2-wire)
Zero and Span Adjustments Push-button
Loop Resistance 0 to 1250 Ω maximum
Current Consumption 21 mA maximum
Connections Electrical: Screw-type terminals
Process: Male ports on side for ⅛”, 316“, ¼”, 0.2″ (5 mm), 0.23″ (6 mm) ID flexible tubing
Power Requirements 10 to 35 V DC (2-wire)
Enclosure Rating NEMA 4X (IP66)
Mounting Orientation Not sensitive to position
Agency Approvals CE
Housing Material Polycarbonate
Dimensions Ø5 x 1.9″ (Ø127 x 48.2 mm)
Weight 7.04 oz (200 g)

What’s included with the Dwyer DM-008

  • Dwyer DM-008 DigiMag Differential Pressure Transmitter, 5 inWC

Dwyer DM-202 DigiMag Differential Pressure Transmitter, ±0.25 inWC

Dwyer DM-202 DigiMag Differential Pressure Transmitter, ±0.25 inWC

  • Model: DM-202

Senses the pressure of air and compatible gases, this differential pressure transmitter features a pressure range of ±0.25 inWC and has a 4 to 20 mA output. Fast and easy to set up, this transmitter is suitable for fan control, static pressures in ducts or buildings, room pressurization monitoring, and differential pressure across filters.

Dwyer DM-202 Offers

Specifically designed to mount in a standard Magnehelic® gauge cutout, this pressure transmitter features a polycarbonate molded housing with integral pressure connections, reducing installation time. In addition, the digital push-button zero and span simplify calibration over typical turn-potentiometers, and a single push-button allows field selection of multiple engineering units.

Features

  • Reduced installation time through zero and span controls that provides quick and easy calibration
  • Fast and easy setup and calibration with push-button zero and span controls
  • Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
  • Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic® gauge, as both use the same diameter cutout

Applications

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
  • Room pressurization monitoring

Dwyer DM-202 Specifications

Service Air and non-combustible, compatible gases
Pressure Range ±0.25 inWC
Accuracy ±2% FSO
Stability <±1%/year FSO
Limits Pressure: 3.6 psi maximum operation, 6 psi burst
Temperature: -4 to 158°F (-20 to 70°C)
Thermal Effect 0.02% FS/°F (0.036% FS/°C)
Output Signal 4 to 20 mA (2-wire)
Zero and Span Adjustments Push-button
Loop Resistance 0 to 1250 Ω maximum
Current Consumption 21 mA maximum
Connections Electrical: Screw-type terminals
Process: Male ports on side for ⅛”, 316“, ¼”, 0.2″ (5 mm), 0.23″ (6 mm) ID flexible tubing
Power Requirements 10 to 35 V DC (2-wire)
Enclosure Rating NEMA 4X (IP66)
Mounting Orientation Not sensitive to position
Agency Approvals CE
Housing Material Polycarbonate
Dimensions Ø5 x 1.9″ (Ø127 x 48.2 mm)
Weight 7.04 oz (200 g)

What’s included with the Dwyer DM-202

  • Dwyer DM-202 DigiMag Differential Pressure Transmitter, ±0.25 inWC

Dwyer DM-203 DigiMag Differential Pressure Transmitter, ±0.5 inWC

Dwyer DM-203 DigiMag Differential Pressure Transmitter, ±0.5 inWC

  • Model: DM-203

Senses the pressure of air and compatible gases, this differential pressure transmitter features a pressure range of ±0.5 inWC and has a 4 to 20 mA output. Fast and easy to set up, this transmitter is suitable for fan control, static pressures in ducts or buildings, room pressurization monitoring, and differential pressure across filters.

Dwyer DM-203 Offers

Specifically designed to mount in a standard Magnehelic® gauge cutout, this pressure transmitter features a polycarbonate molded housing with integral pressure connections, reducing installation time. In addition, the digital push-button zero and span simplify calibration over typical turn-potentiometers, and a single push-button allows field selection of multiple engineering units.

Features

  • Reduced installation time through zero and span controls that provides quick and easy calibration
  • Fast and easy setup and calibration with push-button zero and span controls
  • Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
  • Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic® gauge, as both use the same diameter cutout

Applications

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
  • Room pressurization monitoring

Dwyer DM-203 Specifications

Service Air and non-combustible, compatible gases
Pressure Range ±0.5 inWC
Accuracy ±1% FSO
Stability <±1%/year FSO
Limits Pressure: 3.6 psi maximum operation, 6 psi burst
Temperature: -4 to 158°F (-20 to 70°C)
Thermal Effect 0.02% FS/°F (0.036% FS/°C)
Output Signal 4 to 20 mA (2-wire)
Zero and Span Adjustments Push-button
Loop Resistance 0 to 1250 Ω maximum
Current Consumption 21 mA maximum
Connections Electrical: Screw-type terminals
Process: Male ports on side for ⅛”, 316“, ¼”, 0.2″ (5 mm), 0.23″ (6 mm) ID flexible tubing
Power Requirements 10 to 35 V DC (2-wire)
Enclosure Rating NEMA 4X (IP66)
Mounting Orientation Not sensitive to position
Agency Approvals CE
Housing Material Polycarbonate
Dimensions Ø5 x 1.9″ (Ø127 x 48.2 mm)
Weight 7.04 oz (200 g)

What’s included with the Dwyer DM-203

  • Dwyer DM-203 DigiMag Differential Pressure Transmitter, ±0.5 inWC