GEMS 3100 Series Pressure Transmitter is a compact and reliable pressure measurement device designed for industrial pressure monitoring and control applications.It uses sputtered thin-film sensing technology and stainless-steel wetted construction for stable performance in demanding environments.The Pressure Range is 0 to 400 Bar
Technical Data
Product Series:GEMS 3100 Series
Part No:3100S0400S05B000
Pressure Range:0 to 400 Bar
Supply:12-32 VDC
OUTPUT:0…10 V
CONNECTION:1/4″ NPT 304 SS
Pressure Type:Gauge / Sealed Gauge,Depending on Configuration
Accuracy:Typically 0.25% Full Scale
Operating Temperature:
Approximately-40°C to +125°C Configuration Dependent
High Proof And Burst Pressure Capability
Stainless-Steel Wetted Parts
Protection: Up to IP67,Configuration Dependent
Product Features
0–400 Bar high-pressure measurement
Excellent long-term stability
Sputtered thin-film sensing technology
Stainless-steel construction
Compact size for space-limited installations
Reliable performance under demanding industrial conditions
Multiple electrical and pressure connection options available within the 3100 Series
Field Of Application
Hydraulic Systems,Pneumatic Systems,Industrial Machinery,Compressors, Pumps,Process Equipment,Hydraulic Power Units,Water Systems,Oil & Gas Equipment,Chemical Processing,Industrial Automation,Refrigeration Systems and General Pressure Monitoring
Ambient Condition
Operating Temperature is Typically-40°C to +125°C,Depending on the Selected configuration.Proper installation should protect the transmitter from excessive vibration,Mechanical shock and temperatures outside the specified range
Material
Wetted Parts:Stainless Steel
Housing:Stainless Steel,Configuration Dependent
Industrial compact construction
Sealing and Connection materials depend on the selected configuration.
Electrical Data
The GEMS 3100 Series is Available with Different Electrical Outputs and connections.Common configurations include 4–20 mA,0–10 V and ratiometric outputs,With supply voltage depending on the selected model The exact electrical specification should be confirmed against the complete part-number configuration before installation
Installation Guide
Install the Transmitter on a Compatible pressure port using the correct thread and sealing method.Ensure the pressure line is clean and free from contamination.Connect the electrical supply and output according to the applicable wiring diagram.Do not exceed the specified pressure,Temperature or electrical limits.After installation, check for leakage and verify the output signal before putting the system into service
Approval
RoHS compliant.Additional approvals/certifications may depend on the Selected 3100 Series Configuration
Accessories
Mating Electrical Connector,Pressure Fittings,adapters,Mounting accessories,Seals and Compatible cables may be Available Depending on the selected Configuration
Note: Specifications such as output,Pressure Connection,Supply Voltage, IP rating and certification can vary by exact GEMS 3100 Configuration. Always Verify the Original Manufacturer Datasheet Before Final Installation Or Ordering
Temperature: Approximately -40°C to +125°C, configuration dependent
Compliance: RoHS
Product Features
0–250 Bar Pressure Range
0–10 VDC Analogue Output
12–30 VDC supply
Robust industrial construction
Stainless-steel wetted construction
Reliable thin-film sensing technology
Designed for demanding high-pressure applications
Compact and durable design
Suitable for continuous pressure monitoring
Field Of Application
Suitable for Hydraulic Systems, Pumps, Compressors, Industrial Machinery, Process Equipment, Water Treatment, Oil & Gas Equipment, Chemical Plants, Boiler Systems, Air & Gas Systems, HVAC, Industrial Automation and OEM Machinery. Ambient Condition
Install within the specified pressure and temperature limits. Protect the transmitter from excessive vibration, mechanical shock, moisture and freezing. Ensure that the pressure medium is compatible with the wetted materials. Do not exceed the rated pressure or temperature limits. Material
The 3200 Series Uses Robust Stainless-Steel Construction suitable for industrial pressure measurement. Exact wetted material and pressure-port specification should be verified from the complete part-number configuration. Electrical Data
Output: 0–10 VDC
Supply Voltage: 12–30 VDC
Signal: Analogue Voltage
Use a suitable regulated DC power supply.
Connect wiring according to the applicable connector pinout.
Installation Guide
Verify part number and pressure range before installation.
Confirm system pressure is within the transmitter’s rated range.
Check pressure-medium compatibility.
Install the correct pressure connection and seal.
Connect electrical wiring according to the supplied pinout.
Apply pressure gradually and check for leakage.
Never exceed the specified maximum pressure.
Approval