SETRA Model 3200B0060G05BR2is a Heavy-Duty Industrial OEM Pressure Transmitter Designed For Accurate and Reliable Measurement of Pressure up to 0–60 Bar.The Model 3200 Uses Sputtered thin-film sensing technology,Rugged stainless-steel construction and compact Design for Demanding Industrial Applications.SETRA Model 3200 is Available With Different Electrical Outputs and Connection Configurations.
Technical Data
Brand: SETRA
Model: 3200
Part No.: 3200B0060G05BR2
Pressure Range: 0–60 Bar
Type: Gauge Pressure Transmitter
Supply: 8-32 VDC
OUTPUT: 4…20 mA
CONNECTION: 1/4″ NPT 304 SS.
COUNTRY OF ORIGIN: INDIA
Sensing Technology: Sputtered Thin Film
Accuracy: Configuration dependent; Model 3200 Specifications Are Available up to ±0.25% FS / ±0.5% FS Depending On Product Configuration
Response Time: Approximately 1 ms
Construction: Heavy-Duty Industrial
Protection: IP67 depending on configuration
Product Features
Heavy-duty industrial Design
Rugged all-welded Stainless-Steel Construction
Excellent long-term stability
Compact size for OEM installation
Fast response
High resistance to vibration and harsh industrial environments
Reverse wiring protection
Multiple electrical output and pressure connection options
Field Of Application
Suitable for Hydraulic Systems,Industrial Machinery,Compressors,Pumps, Process Equipment,Power-Generation Equipment,Irrigation Systems,OEM Machinery,Pressure Monitoring And Industrial Automation Applications.
Ambient Condition
Operating and Compensated Temperature range can extend approximately from -40°C to +125°C, depending on configuration.The Transmitter should be protected from pressure,Temperature And Environmental Conditions Outside its Specified Limits.
Material
Sensing Diaphragm: 17-4 PH Stainless Steel
Fittings/wetted components: 304 stainless steel,Depending on Configuration
Housing: Rugged stainless-steel construction
Electrical Data
Model 3200 Configurations Are Available With 4–20 mA, 0–10 VDC, 0–5 VDC, 1–5 VDC, 1–6 VDC and ratiometric outputs.Supply Voltage and Electrical Connector Depend on the exact part-number Configuration.
Installation Guide
Install The Transmitter on the correct pressure port using suitable fittings and sealing. Keep the pressure connection Clean and avoid excessive vibration or mechanical stress. Connect electrical wiring according to the Applicable SETRA wiring Diagram.Do not exceed the rated pressure, temperature or electrical limits. Verify the complete configuration before commissioning.
Approval
Model 3200 is Designed For Industrial Applications and is Available with RoHS compliance and CE-related EMC Requirements,Depending on configuration. Exact approvals should be Verified for the Ordered Part Number.
Accessories
Suitable Accessories May Include Pressure Fittings,Adapters,Electrical Connectors,Cables,Mounting Accessories and Pressure Restrictors.Select Accessories According to the Exact Transmitter Configuration.
The SETRA Model 3200 is a heavy-duty industrial OEM pressure Transducer using a sputtered thin-film sensing element. The Model 3200 is designed for demanding industrial applications and is available with Different Pressure Ranges, outputs, pressure ports and electrical connections.
Product Information
Brand: SETRA
Model: 3200
Part No.: 3200B0100S05BO2
Type: Pressure Transmitter / Pressure Transducer
Pressure Range: 0 to 100 Bar
Pressure Type: Gauge
Technology: Sputtered Thin-Film
Construction: All-welded stainless steel
Protection: IP67
Accuracy: Model 3200 specifications vary by configuration; the current SETRA product page lists up to ±0.25% FS, while the referenced 3200 datasheet lists ±0.5% FS. Verify the exact part-number configuration before publishing a guaranteed accuracy.
Technical Data
Parameter
Specification
Model
SETRA 3200
Part Number
3200B0100S05BO2
Range
0–100 Bar
Sensing Technology
Sputtered Thin Film
Accuracy
Configuration dependent
Pressure Type
Gauge
Wetted Material
17-4 PH Stainless Steel diaphragm; 304 SS fittings
Enclosure
IP67
Response Time
Approx. 1 ms
Operating Temperature
-40°C to +125°C
Storage Temperature
-40°C to +125°C
Construction
All-welded stainless steel
Overpressure
Up to 3 × FS depending on pressure range/configuration
Long-Term Stability
±0.2% FS for ranges below 60 Bar in referenced datasheet
The 0–100 Bar range is within the Model 3200’s published range options.
Product Features
Heavy-duty industrial design
Sputtered thin-film pressure sensing
Compact construction
All-welded stainless-steel body
IP67 environmental protection
Excellent long-term stability
High resistance to vibration
Reverse-wiring protection
Multiple electrical output options
No oil-filled sensing system
Designed for OEM and industrial applications
RoHS compliant
CE/UL approvals available depending on configuration
Field of Application
Suitable applications include:
Industrial machinery
Hydraulic systems
Pneumatic systems
Compressors
Pumps
Process equipment
Chemical processing
Oil & gas equipment
Water-treatment equipment
HVAC and building equipment
OEM machinery
Factory automation
Heavy industrial equipment
Pressure monitoring and control systems
SETRA states that its pressure transmitters are designed for applications involving both liquids and gases, subject to material compatibility.
Ambient Condition
Operating temperature: approximately -40°C to +125°C
Storage temperature: approximately -40°C to +125°C
Protection: IP67
Suitable for demanding industrial environments
High vibration resistance
Media must be compatible with the wetted materials.
Material
Wetted Parts:
17-4 PH Stainless Steel diaphragm
304 Stainless Steel fittings
Body/Construction:
Stainless-steel construction
All-welded design
The exact pressure-port material/configuration should be confirmed against the individual part-number ordering code.
Electrical Data
The Model 3200 platform supports different electrical configurations, depending on the ordered part number:
Current Output
Output: 4–20 mA
Circuit: 2-wire
Excitation: 8–30 VDC
Voltage Outputs
0–10 VDC
0–5 VDC
1–5 VDC
1–6 VDC
0.5–4.5 VDC
Ratiometric
0.5–4.5 VDC
5 VDC nominal excitation
The exact output for 3200B0100S05BO2 should be confirmed from the manufacturer’s ordering configuration before specifying it on a product listing.
Installation Guide
Confirm that the pressure range and pressure medium are suitable.
Install the transmitter using the correct pressure connection.
Do not exceed the rated pressure range during normal operation.
Connect the electrical supply according to the applicable wiring diagram.
Use appropriate shielded cable where required by the installation environment.
Ensure proper grounding for metal housings/enclosures.
Avoid excessive mechanical stress on the pressure port and electrical connector.
Check for leakage after installation.
Apply pressure gradually during commissioning.
SETRA’s installation instructions specify that the Model 3100/3200 is designed for gases or liquids compatible with 17-4 PH stainless steel and provide separate wiring arrangements for voltage and current outputs.
Approval & Compliance
Depending on configuration, the Model 3200 platform is specified with:
CE
UL
RoHS
IP67 protection
Approval availability can depend on the exact electrical and mechanical configuration.